Journal of Applied Physiology AJP: Gastrointestinal and Liver Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 48: 710-716, 1980;
8750-7587/80 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bohn, D. J.
Right arrow Articles by Bryan, A. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bohn, D. J.
Right arrow Articles by Bryan, A. C.

Journal of Applied Physiology, Vol 48, Issue 4 710-716, Copyright © 1980 by American Physiological Society


ARTICLES

Ventilation by high-frequency oscillation

D. J. Bohn, K. Miyasaka, B. E. Marchak, W. K. Thompson, A. B. Froese and A. C. Bryan

The effect of applying a high-frequency small-volume sinusoidal oscillation at the airway was investigated in anesthetized apneic beagle dogs (mean wt 11 kg, mean VDphys 6.6 +/- 0.6 ml/kg). Oscillations generated by a piston in a cylinder were transmitter to the lungs through an uncuffed endotracheal tube (4.5 mm ID, 6.0 mm OD), which allowed a substantial leak back through the vocal cords. A bias flow of fresh gas presented inspired air to the midtracheal level. The minimum distal airway pressure (measured at the end of the endotracheal tube) was maintained between 0 and 2 cmH2O. Peak airway pressures were 4-8 cmH2O. The optimal frequency for CO2 elimination was 15 Hz. Using volumes of 1.9 ml/kg (range 1.7-2.3) at this frequency the mean PaCO2 was 33.1 +/- 0.5 Torr. In four dogs breathing 100% O2 the PaO2 was 594 +/- 9 Torr during spontaneous ventilation and 580 +/- 9 Torr after 5 h of uninterrupted oscillation. In four experiments using room air the PaO2 was 95 +/- 5 Torr during spontaneous respiration and 106 +/- 1 Torr after 5 h of oscillation. In an additional seven studies there was no difference in mean cardiac output between oscillation and conventional mechanical ventilation. This study demonstrates that high-frequency small-volume oscillations can maintain gas exchange for many hours presumably by markedly enhancing the diffusivity of gases in the lung.


This article has been cited by other articles:


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
G Lista, F Castoldi, S Bianchi, M Battaglioli, F Cavigioli, and M A Bosoni
Volume guarantee versus high-frequency ventilation: lung inflammation in preterm infants
Arch. Dis. Child. Fetal Neonatal Ed., July 1, 2008; 93(4): F252 - F256.
[Abstract] [Full Text] [PDF]


Home page
NeoReviewsHome page
W. E. Truog
Chronic Lung Disease and Randomized Interventional Trials: Status in 2005
NeoReviews, June 1, 2005; 6(6): e278 - e288.
[Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
F. Cools and M. Offringa
Meta-analysis of elective high frequency ventilation in preterm infants with respiratory distress syndrome
Arch. Dis. Child. Fetal Neonatal Ed., January 1, 1999; 80(1): 15F - 20.
[Abstract] [Full Text]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
G Dimitriou, A Greenough, V Kavvadia, B Laubscher, and A D Milner
Volume delivery during high frequency oscillation
Arch. Dis. Child. Fetal Neonatal Ed., March 1, 1998; 78(2): 148F - 150.
[Abstract] [Full Text]


Home page
J. Appl. Physiol.Home page
K. Kolandaivelu and C.-S. Poon
A miniature mechanical ventilator for newborn mice
J Appl Physiol, February 1, 1998; 84(2): 733 - 739.
[Abstract] [Full Text] [PDF]


Home page
J Intensive Care MedHome page
C. E. Blanco, W. J. Maertzdorf, and F. J. Walther
Use of Combined Higb-Frequency Oscillation and Intermittent Mandatory Ventilation in Rabbits with Saline-Lavaged Lungs
J Intensive Care Med, August 1, 1987; 2(4): 214 - 217.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online