Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 48: 648-656, 1980;
8750-7587/80 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cotton, D. J.
Right arrow Articles by Graham, B. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cotton, D. J.
Right arrow Articles by Graham, B. L.

Journal of Applied Physiology, Vol 48, Issue 4 648-656, Copyright © 1980 by American Physiological Society


ARTICLES

Effect of ventilation and diffusion nonuniformity on DLCO (exhaled) in a lung model

D. J. Cotton and B. L. Graham

Recent studies have shown that diffusing capacities measured at multiple intervals during a single exhalation [DLCO(exhaled)] remained constant with lung volume in normal subjects, but decreased with decreasing lung volume in patients who may have had diffusion nonuniformity. We have examined the theoretical basis of these results by determining what factors affected DLCO(exhaled) in a computerized lung model in which diffusion in each compartment remained constant with lung volume. DLCO(exhaled) decreased with decreasing lung volume when a small lung region lacked diffusion. However, the change in DLCO(exhaled) with lung volume was also affected by nonuniform ventilation and these effects could not be eliminated by correcting the carbon monoxide decay and the simultaneous decay of helium. DLCO(exhaled) values were also influenced by the exhaled flow rate in the presence of nonuniform ventilation and/or nonuniform diffusion. However, prolonging the period of breath holding prior to exhalation reduced DLCO(exhaled) values at all lung volumes when non-uniform diffusion was simulated, but did not affect DLCO(exhaled) when only nonuniform ventilation was simulated.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
S. Verbanck, D. Schuermans, S. Van Malderen, W. Vincken, and B. Thompson
The effect of conductive ventilation heterogeneity on diffusing capacity measurement
J Appl Physiol, April 1, 2008; 104(4): 1094 - 1100.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
M. J. M. Horstman, F. W. Mertens, D. Schotborg, H. C. Hoogsteden, and H. Stam
Comparison of Total-Breath and Single-Breath Diffusing Capacity in Healthy Volunteers and COPD Patients
Chest, January 1, 2007; 131(1): 237 - 244.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
Y.-C. T. Huang, S. R. O'Brien, and N. R. MacIntyre
Intrabreath Diffusing Capacity of the Lung in Healthy Individuals at Rest and During Exercise*
Chest, July 1, 2002; 122(1): 177 - 185.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
I. B. Perillo, R. W. Hyde, A. J. Olszowka, A. P. Pietropaoli, L. M. Frasier, A. Torres, P. T. Perkins, R. E. Forster II, M. J. Utell, and M. W. Frampton
Chemiluminescent measurements of nitric oxide pulmonary diffusing capacity and alveolar production in humans
J Appl Physiol, November 1, 2001; 91(5): 1931 - 1940.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online