Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 48: 370-375, 1980;
8750-7587/80 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stengel, P. W.
Right arrow Articles by Weber, K. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stengel, P. W.
Right arrow Articles by Weber, K. C.

Journal of Applied Physiology, Vol 48, Issue 2 370-375, Copyright © 1980 by American Physiological Society


ARTICLES

Lung degassing: an evaluation of two methods

P. W. Stengel, D. G. Frazer and K. C. Weber

This study compares the effectiveness of the oxygen absorption and vacuum degassing methods for removing trapped gas from lungs. In addition, the effects of changing vacuum pressure, number of times to degas, and lung orientation during the vacuum degassing procedure were evaluated. To evaluate the two methods, a capacitance spirometer was designed and constructed to record lung volume as lungs were vacuum degassed. When lungs containing trapped gas were degassed in a vacuum chamber, they initially expanded, then slightly decreased in volume until the vacuum was released. Lung volume rapidly decreased as the pressure in the vacuum chamber returned to ambient pressure. The results showed that oxygen absorption atelectasis was more effective in removing gas from the lungs than vacuum degassing the lungs. When vacuum degassing was use, it was found to be most effective when the pressure in the chamber was reduced to the vaporization pressure of H2O and when the lungs were degassed twice. Degassing the lungs more than twice did not significantly remove more gas from the lungs. Lung orientation did not affect the removal of gas during vacuum degassing.


This article has been cited by other articles:


Home page
Proc. Natl. Acad. Sci. USAHome page
A. Sato, T. Hirai, A. Imura, N. Kita, A. Iwano, S. Muro, Y.-i. Nabeshima, B. Suki, and M. Mishima
Morphological mechanism of the development of pulmonary emphysema in klotho mice
PNAS, February 13, 2007; 104(7): 2361 - 2365.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
P. B. Noble, A. Sharma, P. K. McFawn, and H. W. Mitchell
Airway narrowing in porcine bronchi with and without lung parenchyma
Eur. Respir. J., November 1, 2005; 26(5): 804 - 811.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Regul. Integr. Comp. Physiol.Home page
D. M. Gries, E. K. Tam, J. M. Blaisdell, L. M. Iwamoto, N. Fujiwara, C. F. T. Uyehara, and K. T. Nakamura
Differential effects of inhaled nitric oxide and hyperoxia on pulmonary dysfunction in newborn guinea pigs
Am J Physiol Regulatory Integrative Comp Physiol, November 1, 2000; 279(5): R1525 - R1530.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
C. H. Durney, A. G. Cutillo, and D. C. Ailion
Magnetic resonance behavior of normal and diseased lungs: spherical shell model simulations
J Appl Physiol, April 1, 2000; 88(4): 1155 - 1166.
[Abstract] [Full Text] [PDF]


Home page
J. Biol. Chem.Home page
H. T. Akinbi, J. S. Breslin, M. Ikegami, H. S. Iwamoto, J. C. Clark, J. A. Whitsett, A. H. Jobe, and T. E. Weaver
Rescue of SP-B Knockout Mice with a Truncated SP-B Proprotein. FUNCTION OF THE C-TERMINAL PROPEPTIDE
J. Biol. Chem., April 11, 1997; 272(15): 9640 - 9647.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online