Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 47: 1234-1238, 1979;
8750-7587/79 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Onal, E.
Right arrow Articles by Evanich, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Onal, E.
Right arrow Articles by Evanich, M. J.

Journal of Applied Physiology, Vol 47, Issue 6 1234-1238, Copyright © 1979 by American Physiological Society


ARTICLES

Effects of electrode position on esophageal diaphragmatic EMG in humans

E. Onal, M. Lopata and M. J. Evanich

The effects of electrode position and gastric-balloon anchoring on esophageal diaphragmatic EMG (EMGdi) responses to CO2 rebreathing were studied in seven normal sitting humans using an esophageal catheter that consisted of four platinum wire coils enabling simultaneous recording of three EMGdi signals from three different sites in the esophagus. A gastric balloon attached to the distal end of the catheter allowed anchoring of the catheter. EMGdi signals were quantitated as a moving time average. Two rebreathing experiments were performed with and without balloon anchoring on the same day. Changes in electrode position of at least 2 cm above the site of maximum EMGdi activity caused minimal changes in the moving average EMGdi and did not significantly effect the quantitated EMGdi response to CO2 rebreathing. The maximum EMGdi activity was approximately 2 cm above the gastroesophageal junction in sitting humans. Stabilization of the catheter with an inflated gastric balloon did not improve the reproducibility of the EMGdi data. Finally, the EMGdi response to two CO2 rebreathing runs done at the same sitting showed intraindividual reproducibility.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
Y. M. Luo, N. Hart, N. Mustfa, R. A. Lyall, M. I. Polkey, and J. Moxham
Effect of diaphragm fatigue on neural respiratory drive
J Appl Physiol, May 1, 2001; 90(5): 1691 - 1699.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
B. Fauroux, D. Isabey, G. Desmarais, L. Brochard, A. Harf, and F. Lofaso
Nonchemical influence of inspiratory pressure support on inspiratory activity in humans
J Appl Physiol, December 1, 1998; 85(6): 2169 - 2175.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online