Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 47: 1148-1156, 1979;
8750-7587/79 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Laughlin, M. H.
Right arrow Articles by Loxsom, F. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Laughlin, M. H.
Right arrow Articles by Loxsom, F. M.

Journal of Applied Physiology, Vol 47, Issue 6 1148-1156, Copyright © 1979 by American Physiological Society


ARTICLES

Use of microspheres in measurement of regional blood flows during +GZ stress

M. H. Laughlin, J. W. Burns and F. M. Loxsom

The use of the radiolabeled microsphere technique for the study of the effects of +GZ acceleration on regional blood flow is examined. A theoretical analysis of the limits of this technique in a high acceleration environment is presented. Chronically implanted, electromagnetic, aortic flow probes were used to determine the relationship between aortic blood flow velocity and +GZ acceleration in conscious adult miniature swine. It was found that conscious straining adult miniature swine, with the assistance of an inflated anti-G suit, are able to compensate quite well to acceleration levels less than or equal to +7 GZ. Exposure to +9 GZ often resulted in unstable cardiovascular states involving relative bradycardia, often progressing to asystole, declining aortic blood pressure, and markedly diminished cardiac outputs approaching zero. It was found that, if aortic pressure and heart rate attain a relatively steady state during acceleration, and if heart level mean aortic pressure is greater than or equal to 100 Torr, the application of the microsphere technique during +GZ acceleration is theoretically valid. This hypothesis was tested using the microsphere technique (9.0 +/- 0.8 microns diam) in conscious miniature swine during exposure to +GZ acceleration. It is concluded that within the defined limits the radiolabeled microsphere technique is as accurate for use during acceleration studies as it is for use in routine laboratory studies.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
M. A. Chornuk, S. L. Bernard, J. W. Burns, R. W. Glenny, D. D. Sheriff, S. E. Sinclair, N. L. Polissar, and M. P. Hlastala
Effects of inertial load and countermeasures on the distribution of pulmonary blood flow
J Appl Physiol, August 1, 2000; 89(2): 445 - 457.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. P. Hlastala, M. A. Chornuk, D. A. Self, H. J. Kallas, J. W. Burns, S. Bernard, N. L. Polissar, and R. W. Glenny
Pulmonary blood flow redistribution by increased gravitational force
J Appl Physiol, April 1, 1998; 84(4): 1278 - 1288.
[Abstract] [Full Text] [PDF]