Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 47: 462-467, 1979;
8750-7587/79 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jackson, A. C.
Right arrow Articles by Vinegar, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jackson, A. C.
Right arrow Articles by Vinegar, A.

Journal of Applied Physiology, Vol 47, Issue 2 462-467, Copyright © 1979 by American Physiological Society


ARTICLES

A technique for measuring frequency response of pressure, volume, and flow transducers

A. C. Jackson and A. Vinegar

A device and methodology is presented for testing the frequency response of pressure, volume, or flow transducers. Also reported are responses of selected transducers of all three types over the range of 2--120 Hz. Several pressure transducers tested had good frequency response when connected to the test system with a minimum of interconnecting fittings; others did not. Use of additional connectors degraded the response as did the addition of air-filled catheters. The frequency response of the pneumotachometers tested were influenced largely by the response characteristics of the associated pressure transducer and interconnecting fittings. These results emphasize the need to test the response characteristics of any transducer with specific connectors and fittings that are to be used to make the actual measurements of pressure, volume, or flow.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
ATS/ERS Statement on Respiratory Muscle Testing
Am. J. Respir. Crit. Care Med., August 15, 2002; 166(4): 518 - 624.
[Full Text] [PDF]


Home page
J. Exp. Biol.Home page
P. Nassar, A. Jackson, and D. Carrier
Entraining the natural frequencies of running and breathing in guinea fowl (Numida meleagris)
J. Exp. Biol., May 1, 2001; 204(9): 1641 - 1651.
[Abstract] [PDF]


Home page
Eur Respir JHome page
U. Frey, B. Reinmann, and J. Stocks
The infant lung function model: a mechanical analogue to test infant lung function equipment
Eur. Respir. J., April 1, 2001; 17(4): 755 - 764.
[Abstract] [Full Text] [PDF]


Home page
Eur Respir JHome page
B. Reinmann, J. Stocks, and U. Frey
Assessment of an infant whole-body plethysmograph using an infant lung function model
Eur. Respir. J., April 1, 2001; 17(4): 765 - 772.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. R. MILLER, B. JONES, Y. XU, O. F. PEDERSEN, and P. H. QUANJER
Peak Expiratory Flow Profiles Delivered by Pump Systems . Limitations due to Wave Action
Am. J. Respir. Crit. Care Med., June 1, 2000; 161(6): 1887 - 1896.
[Abstract] [Full Text]


Home page
J. Appl. Physiol.Home page
S. A. Tuck, J. C. Dort, M. E. Olson, and J. E. Remmers
Monitoring respiratory function and sleep in the obese Vietnamese pot-bellied pig
J Appl Physiol, July 1, 1999; 87(1): 444 - 451.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. F. Sobh, C. M. Lilly, J. M. Drazen, and A. C. Jackson
Respiratory transfer impedance between 8 and 384 Hz in guinea pigs before and after bronchial challenge
J Appl Physiol, January 1, 1997; 82(1): 172 - 181.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online