Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 46: 998-1002, 1979;
8750-7587/79 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Haddad, G. G.
Right arrow Articles by Mellins, R. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haddad, G. G.
Right arrow Articles by Mellins, R. B.

Journal of Applied Physiology, Vol 46, Issue 5 998-1002, Copyright © 1979 by American Physiological Society


ARTICLES

Maturation of ventilation and ventilatory pattern in normal sleeping infants

G. G. Haddad, R. A. Epstein, M. A. Epstein, H. L. Leistner, P. A. Marino and R. B. Mellins

Noninvasive studies of ventilation and ventilatory pattern were performed serially in 15 normal infants in the first 4 mo of life during REM and quiet sleep with the barometric method. We measured tidal volume (VT), total respiratory cycle time (Ttot), inspiratory time (Ti), expiratory time (TE), mean inspiratory flow (VT/TI), and respiratory "duty cycle" (TI/Ttot). Vt, Ttot, TI, TE, VT/TI, and VT/Ttot but not TI/Ttot increased with age. In all age groups, Ttot, TI, and TE but not VT/TI were greater in quiet than in REM sleep. In the first 2 mo of life, VT was greater in quiet than in REM sleep; in the older infants, VT/Ttot was smaller in quiet than in REM sleep. TI/Ttot was not dependent on sleep state. Thus, because VT/Ttot = VT/TI X TI/Ttot, the increase in VT/Ttot with age results from an increase in mean inspiratory flow rather than from changes in respiratory "duty cycle". Further, the "on-switching" as well as the "off-switching" of inspiratory activity depends on sleep state.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
A. Adler, G. Cieslewicz, and C. G. Irvin
Unrestrained plethysmography is an unreliable measure of airway responsiveness in BALB/c and C57BL/6 mice
J Appl Physiol, July 1, 2004; 97(1): 286 - 292.
[Abstract] [Full Text] [PDF]


Home page
Physiol. Rev.Home page
G. Hilaire and B. Duron
Maturation of the Mammalian Respiratory System
Physiol Rev, April 1, 1999; 79(2): 325 - 360.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online