Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 46: 890-896, 1979;
8750-7587/79 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lloyd, T. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lloyd, T. C., Jr

Journal of Applied Physiology, Vol 46, Issue 5 890-896, Copyright © 1979 by American Physiological Society


ARTICLES

Effects of extrapulmonary airway distension on breathing in anesthetized dogs

T. C. Lloyd Jr

Anesthetized dogs with open chests were perfused with a pump-oxygenator. We first observed the effects of intermittent periods of sustained inflation of both lungs, of only one lobe, and of an intra-airway balloon on the diaphragm electromyogram (EMG). Lung or lobe inflation with low pressures depressed respiratory frequency (fr) by prolonging expiratory time (TE) in proportion to inflating pressure, but balloon inflation was without effect. We next intermittently inflated one or two lobes after all others were ligated and thereafter inflated all the extrapulmonary airways following total lung excision. Lobe inflation, by varying TE, decreased fr at low pressures and often increased fr at higher pressures. Extrapulmonary airway distension slightly increased fr and the mean rate of rise of the integrated EMG, but decreased inspiratory time and peak EMG amplitude. TE was slightly prolonged by low pressures when using sustained airway pressurization but was shortened by higher pressures when distending cyclically. In comparison to lobe inflation, the effects from isolated airways were small, and the inhibitory effect of lung inflation could not be attributed to them.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
H. SCHNEIDER, D. J. O'HEARN, K. LEBLANC, P. L. SMITH, C. P. O'DONNELL, D. W. EISELE, J. H. PETER, and A. R. SCHWARTZ
High-flow Transtracheal Insufflation Treats Obstructive Sleep Apnea . A Pilot Study
Am. J. Respir. Crit. Care Med., June 1, 2000; 161(6): 1869 - 1876.
[Abstract] [Full Text]