Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 46: 1-7, 1979;
8750-7587/79 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gross, D.
Right arrow Articles by Macklem, P. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gross, D.
Right arrow Articles by Macklem, P. T.

Journal of Applied Physiology, Vol 46, Issue 1 1-7, Copyright © 1979 by American Physiological Society


ARTICLES

Electromyogram pattern of diaphragmatic fatigue

D. Gross, A. Grassino, W. R. Ross and P. T. Macklem

We studied the effect of breathing at various levels of transdiaphragmatic pressure (Pdi) on the EMG power spectrum of the diaphragm. The diaphragmatic EMG was measured simultaneously with a bipolar esophageal electrode (EE) and surface electrode (SE) placed on the ventral portion of the sixth and seventh intercostal spaces in five normal subjects breathing at functional residual capacity (FRC) against an inspiratory resistance. During each fatigue run the subjects generated a Pdi, with each inspiration, that was 25, 50, or 75% of maximum Pdi (Pdimax) for a period up to 15 min. During runs at 50 and 75% of the Pdimax, which are known to produce fatigue, we found for both EE and SE a progressive increase in the amplitude of the low-frequency (L = 20-46.7 Hz) and a decrease in the high-frequency (H = 150-350 Hz) component of the EMG. These changes were not seen at 25% of Pdimax. The diaphragmatic H/L ratio was independent of Pdi when the diaphragm was not fatigued. H/L fell while the diaphragm performed fatiguing work and this was more rapid at higher Pdi's. It was thus concluded that frequency spectrum analysis of the EMG can detect diaphragmatic fatigue reliably, prior to the time when the diaphragm fails as a pressure generator.


This article has been cited by other articles:


Home page
J. Neurophysiol.Home page
M. H. O'Neal III, E. T. Spiegel, K. H. Chon, and I. C. Solomon
Time-Frequency Representation of Inspiratory Motor Output in Anesthetized C57BL/6 Mice In Vivo
J Neurophysiol, March 1, 2005; 93(3): 1762 - 1775.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
J. E. Holliday and M. Lippmann
Reduction in Ventilatory Response to CO2 With Relaxation Feedback During CO2 Rebreathing for Ventilator Patients
Chest, October 1, 2003; 124(4): 1500 - 1511.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
F. Garcia-Rio, J. M. Pino, A. Ruiz, S. Diaz, C. Prados, and J. Villamor
Accuracy of noninvasive estimates of respiratory muscle effort during spontaneous breathing in restrictive diseases
J Appl Physiol, October 1, 2003; 95(4): 1542 - 1549.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
N Hart, A Hunt, M I Polkey, B Fauroux, F Lofaso, and A K Simonds
Comparison of proportional assist ventilation and pressure support ventilation in chronic respiratory failure due to neuromuscular and chest wall deformity
Thorax, November 1, 2002; 57(11): 979 - 981.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
ATS/ERS Statement on Respiratory Muscle Testing
Am. J. Respir. Crit. Care Med., August 15, 2002; 166(4): 518 - 624.
[Full Text] [PDF]


Home page
ChestHome page
J.-C. Glerant, V. Jounieaux, V. F. Parreira, M. Dury, G. Aubert, and D. O. Rodenstein
Effects of Intermittent Negative Pressure Ventilation on Effective Ventilation in Normal Awake Subjects*
Chest, July 1, 2002; 122(1): 99 - 107.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
C. SINDERBY, J. SPAHIJA, and J. BECK
Changes in Respiratory Effort Sensation Over Time Are Linked to the Frequency Content of Diaphragm Electrical Activity
Am. J. Respir. Crit. Care Med., March 15, 2001; 163(4): 905 - 910.
[Abstract] [Full Text]


Home page
J. Appl. Physiol.Home page
W. H. Thompson, P. Carvalho, J. P. Souza, and N. B. Charan
Effect of expiratory resistive loading on the noninvasive tension-time index in COPD
J Appl Physiol, November 1, 2000; 89(5): 2007 - 2014.
[Abstract] [Full Text] [PDF]


Home page
NeurologyHome page
S. L. Pullman, D. S. Goodin, A. I. Marquinez, S. Tabbal, and M. Rubin
Clinical utility of surface EMG: Report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology
Neurology, July 25, 2000; 55(2): 171 - 177.
[Full Text] [PDF]


Home page
ChestHome page
J. E. Holliday and C. Veremakis
Reduction in Ventilator Response to CO2 With Relaxation Feedback During CO2 Rebreathing in Normal Adults
Chest, May 1, 1999; 115(5): 1285 - 1292.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
J. SUZUKI, R. TANAKA, S. YAN, R. CHEN, P. T. MACKLEM, and B. KAYSER
Assessment of Abdominal Muscle Contractility, Strength, and Fatigue
Am. J. Respir. Crit. Care Med., April 1, 1999; 159(4): 1052 - 1060.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
A. B. Sprikkelman, L. A. Van Eykern, M. S. Lourens, H. S. A. Heymans, and W. M. C. Van Aalderen
Respiratory muscle activity in the assessment of bronchial responsiveness in asthmatic children
J Appl Physiol, March 1, 1998; 84(3): 897 - 901.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. K. McKenzie, G. M. Allen, J. E. Butler, and S. C. Gandevia
Task failure with lack of diaphragm fatigue during inspiratory resistive loading in human subjects
J Appl Physiol, June 1, 1997; 82(6): 2011 - 2019.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
C. A. Sinderby, J. C. Beck, L. H. Lindstrom, and A. E. Grassino
Enhancement of signal quality in esophageal recordings of diaphragm EMG
J Appl Physiol, April 1, 1997; 82(4): 1370 - 1377.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online