Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 45: 733-741, 1978;
8750-7587/78 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fixley, M. S.
Right arrow Articles by Engel, L. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fixley, M. S.
Right arrow Articles by Engel, L. A.

Journal of Applied Physiology, Vol 45, Issue 5 733-741, Copyright © 1978 by American Physiological Society


ARTICLES

Flow dependence of gas distribution and the pattern of inspiratory muscle contraction

M. S. Fixley, C. S. Roussos, B. Murphy, R. R. Martin and L. A. Engel

We measured regional distribution of xenon-133 boli at 0.25, 0.75, and 1.5 l/s in four normal seated subjects during inspirations performed predominantly with intercostal and accessory muscles (IC) or with the diaphragm, accompanied by outward abdominal motion (Ab). In six additional subjects we inferred the topographical distribution of helium boli during similar breaths and flow rates from the slope of the alveolar plateau recorded during a slow expiration (less than 0.5 l/s). Distribution of the helium boli was studied during natural as well as IC and Ab inspirations. At each of the flow rates IC breaths distributed relatively more of the inspired bolus to upper lung regions than did Ab inspirations. Natural breaths at 0.25 l/s resulted in distributions similar to those of Ab inspirations, whereas at 1.5 l/s the distribution approached that of IC inspirations. A three-compartment model, representing upper, middle, and lower lung regions, was used to simulate bolus distribution. The experimental data showed substantial departure from predictions based on regional time constants alone. However, additional small differences in applied pressure (less than 0.50 cmH2O) between the regions satisfactorily accounted for the gas distribution.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online