Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 45: 392-398, 1978;
8750-7587/78 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kim, M. J.
Right arrow Articles by Sharp, J. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kim, M. J.
Right arrow Articles by Sharp, J. T.

Journal of Applied Physiology, Vol 45, Issue 3 392-398, Copyright © 1978 by American Physiological Society


ARTICLES

Effects of lung volume and electrode position on the esophageal diaphragmatic EMG

M. J. Kim, W. S. Druz, J. Danon, W. Machnach and J. T. Sharp

In anesthetized dogs studied both supine and prone, the electromyogram (EMG) of the diaphragm recorded directly from three portions of the diaphragm (crural, anterior, and costal) was compared with simultaneous recordings of the diaphragmatic EMG recorded from 10 sites in the esophagus and stomach. Effects upon the EMG of lung volume change and esophageal electrode position change were determined during bilateral supramaximal tetanic phrenic stimulation with airway occluded. Lung volume change had little effect upon the directly recorded EMG. The effect of lung volume change upon the EMG recorded from the esophagus was somewhat greater and marked change was noted as the esophageal recording site was varied. In supine dogs two sites of maximal signal were observed, one 1 cm above the cardia and the other 4--6 cm below the cardia. In prone dogs a single site for maximal signal was observed 3 cm above the cardia. An electrode site as close to the cardia as possible appears to be optimal from the point of view of variation in signal due to lung volume change and due to body position change. Gastric balloon stabilization is recommended. Proximity of the electrode and posterior gastric wall to the diaphragmatic crura may explain the maximal EMG signal recorded below the cardia.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
ATS/ERS Statement on Respiratory Muscle Testing
Am. J. Respir. Crit. Care Med., August 15, 2002; 166(4): 518 - 624.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
Y. M. Luo, N. Hart, N. Mustfa, R. A. Lyall, M. I. Polkey, and J. Moxham
Effect of diaphragm fatigue on neural respiratory drive
J Appl Physiol, May 1, 2001; 90(5): 1691 - 1699.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
Y. M. LUO, R. A. LYALL, M. LOU HARRIS, G. F. RAFFERTY, M. I. POLKEY, and J. MOXHAM
Quantification of the Esophageal Diaphragm Electromyogram with Magnetic Phrenic Nerve Stimulation
Am. J. Respir. Crit. Care Med., November 1, 1999; 160(5): 1629 - 1634.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online