Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 45: 255-260, 1978;
8750-7587/78 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lai, Y. L.
Right arrow Articles by Hildebrandt, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lai, Y. L.
Right arrow Articles by Hildebrandt, J.

Journal of Applied Physiology, Vol 45, Issue 2 255-260, Copyright © 1978 by American Physiological Society


ARTICLES

Respiratory mechanics in the anesthetized rat

Y. L. Lai and J. Hildebrandt

Functional residual capacity (FRC) and pressure-volume (PV) curves of the lung, chest wall, and total respiratory system were studied in 15 anesthetized rats, weighing 307 +/- 10 (SE) g. Pleural pressure was estimated from the esophageal pressure measured with a water-filled catheter. The FRC determined by body plethysmograph was slightly and significantly larger than FRC determined from saline displacement of excised lungs. The difference may be accounted for by O2 uptake by lung tissue, escape of CO2 through the pleura, and abdominal gas. Paralysis in the prone position did not affect FRC, and abdominal gas content contributed only slightly to the FRC measured by body plethysmograph. Values of various pulmonary parameters (mean +/- SE) were as follows: residual volume, 1.26 +/- 0.13 ml; FRC, 2.51 +/- 0.20 ml; total lung capacity, 12.23 +/- 0.55 ml; compliance of the lung, 0.90 +/- 0.06 ml/cmH2O; chest wall compliance, 1.50 +/- 0.11 ml/cmH2O; and respiratory system compliance, 0.57 +/- 0.03 ml/cmH2O. The lung PV curve did not show a consistent change after the chest was opened.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
R. E. Jacob, K. R. Minard, G. Laicher, and C. Timchalk
3D 3He diffusion MRI as a local in vivo morphometric tool to evaluate emphysematous rat lungs
J Appl Physiol, October 1, 2008; 105(4): 1291 - 1300.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
T. Sera, H. Fujioka, H. Yokota, A. Makinouchi, R. Himeno, R. C. Schroter, and K. Tanishita
Localized compliance of small airways in excised rat lungs using microfocal X-ray computed tomography
J Appl Physiol, May 1, 2004; 96(5): 1665 - 1673.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
J.-D. Ricard, D. Dreyfuss, J.-P. Laissy, and G. Saumon
Dose-Response Effect of Perfluorocarbon Administration on Lung Microvascular Permeability in Rats
Am. J. Respir. Crit. Care Med., December 1, 2003; 168(11): 1378 - 1382.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. Duggan, C. L. McCaul, P. J. McNamara, D. Engelberts, C. Ackerley, and B. P. Kavanagh
Atelectasis Causes Vascular Leak and Lethal Right Ventricular Failure in Uninjured Rat Lungs
Am. J. Respir. Crit. Care Med., June 15, 2003; 167(12): 1633 - 1640.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
L. MARTIN-LEFEVRE, J.-D. RICARD, E. ROUPIE, D. DREYFUSS, and G. SAUMON
Significance of the Changes in the Respiratory System Pressure-Volume Curve during Acute Lung Injury in Rats
Am. J. Respir. Crit. Care Med., August 15, 2001; 164(4): 627 - 632.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
Y.-L. Lai and H.-C. Chou
Respiratory mechanics and maximal expiratory flow in the anesthetized mouse
J Appl Physiol, March 1, 2000; 88(3): 939 - 943.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
W. L. Sexton and D. C. Poole
Effects of emphysema on diaphragm blood flow during exercise
J Appl Physiol, March 1, 1998; 84(3): 971 - 979.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
A. Giannella-Neto, C. Bellido, R. B. Barbosa, and M. F. V. Melo
Design and calibration of unicapillary pneumotachographs
J Appl Physiol, January 1, 1998; 84(1): 335 - 343.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online