Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 45: 18-23, 1978;
8750-7587/78 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Martin, R. J.
Right arrow Articles by Klaus, M. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Martin, R. J.
Right arrow Articles by Klaus, M. H.

Journal of Applied Physiology, Vol 45, Issue 1 18-23, Copyright © 1978 by American Physiological Society


ARTICLES

Effect of lung volume on expiratory time in the newborn infant

R. J. Martin, A. Okken, P. G. Katona and M. H. Klaus

The effect of an increased end-expiratory lung volume on inspiratory and expiratory duration was examined in 13 term infants at 4, 30, and 70 h of age. This was accomplished by the administration of a continuous positive airway pressure (CPAP) of 0, 3, and 6 cmH2O by use of a face mask connected to a pneumotachometer, and by measurement of the timing of the respiratory cycle over 1-min intervals. At increasing functional residual capacity (FRC) there was a progressive increase in expiratory time (TE) and fall in respiratory rate, with a variable effect on inspiratory time (TI). As CPAP increased from 0 to 6 cmH2O, the TI/TE ratio fell from 0.75 to 0.62 (P less than 0.01), 0.90 to 0.66 (P less than 0.001), and 0.87 to 0.64 (P less than 0.001) at 4, 30, and 70 h, respectively. We conclude that alterations in end-expiratory lung volume significantly alter expiratory duration in the newborn infant at term. This may be analogous to the vagally mediated tonic control of expiratory time with changing FRC recently described in anesthetized animals.


This article has been cited by other articles:


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
C. Morley
Continuous distending pressure
Arch. Dis. Child. Fetal Neonatal Ed., September 1, 1999; 81(2): 152F - 156.
[Full Text]


Home page
J. Appl. Physiol.Home page
P. S. Rabbette and J. Stocks
Influence of volume dependency and timing of airway occlusions on the Hering-Breuer reflex in infants
J Appl Physiol, December 1, 1998; 85(6): 2033 - 2039.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
K. Brown, J. Stocks, C. Aun, and P. S. Rabbette
The Hering-Breuer reflex in anesthetized infants: end-inspiratory vs. end-expiratory occlusion technique
J Appl Physiol, April 1, 1998; 84(4): 1437 - 1446.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online