Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 44: 55-58, 1978;
8750-7587/78 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wolfe, L. A.
Right arrow Articles by Rechnitzer, P. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wolfe, L. A.
Right arrow Articles by Rechnitzer, P. A.

Journal of Applied Physiology, Vol 44, Issue 1 55-58, Copyright © 1978 by American Physiological Society


ARTICLES

Reliability of noninvlasive methods for measuring cardiac function in exercise

L. A. Wolfe, D. A. Cunningham, G. M. Davis and P. A. Rechnitzer

Externally recorded systolic time intervals (STI's), indirect (CO2 re-breathing) cardiac output, and auscultatory blood pressures were measured during upright bicycle ergometer work in 20 healthy men, aged 24-56 yr. The subjects were studied on 2 separate days at steady-state work loads chosen to represent light (mean heart rate (HR) = 96 beats.min-1), moderate (HR = 118 beats.min-1) and heavy (HR = 147 beats.min-1) exercise. In addition to determinations of cardiac output, systolic time intervals, and blood pressure, the individual's mean systolic ejection rate (stroke volume/left ventricular ejection time) was calculated as a measure of left ventricular function. In general, heart-rate-corrected STI's were found to be reliable and reproducible. Reliability coefficients for total electromechanical systole and left ventricular ejection time ranged from 0.93 to 0.96 while those for the preejection period and its subcomponents were between 0.63 and 0.88. The reliability of cardiac output, stroke volume, mean systolic ejection rate, and systolic blood pressure was also considered to be acceptable but tended to be higher during moderate and heavy work (r = 0.85-0.95) compared to light exercise (r = 0.60-0.83).





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online