Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 43: 684-688, 1977;
8750-7587/77 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shvartz, E.
Right arrow Articles by Shapiro, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shvartz, E.
Right arrow Articles by Shapiro, Y.

Journal of Applied Physiology, Vol 43, Issue 4 684-688, Copyright © 1977 by American Physiological Society


ARTICLES

Prediction of heat tolerance from heart rate and rectal temperature in a temperate environment

E. Shvartz, S. Shibolet, A. Meroz, A. Magazanik and Y. Shapiro

To determine if heat tolerance could be predicted from responses to exercise in temperature conditions, 51 young men performed 15 min of bench stepping at an average work load of 80 W at 23 degrees C. On the following day they attempted to perform 3 h of bench stepping at 40 W in heat (39.3 degrees C dry bulb, 30.3 degrees C wet bulb). Of these subjects, 4 were heat intolerant, judged by previous heat stroke episodes during field marches, 12 were heat acclimated, and 35 were unacclimated. The heat-intolerant subjects showed the highest heart rates (HR) and rectal temperatures (Tre) at 23 degrees C and in heat, and the acclimated subjects showed the lowest corresponding values. HR and Tre in each environment were combined into a single score, from 10, indicating the poorest responses, to 100, indicating the best responses. These scores at 23 degrees C when correlated with the corresponding scores in heat resulted in a linear correlation coefficient of r = 0.94 with a standard error of estimate of 8.6%. Scores of the heat-intolerant subjects were below 35, and those of the acclimated subjects were between 70 and 100. Thus heat tolerance can accurately be predicted for HR and Tre responses to exercise at room temperature.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online