Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 42: 968-975, 1977;
8750-7587/77 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pearce, D. H.
Right arrow Articles by Reynolds, W. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pearce, D. H.
Right arrow Articles by Reynolds, W. J.

Journal of Applied Physiology, Vol 42, Issue 6 968-975, Copyright © 1977 by American Physiological Society


ARTICLES

Computer-based system for analysis of respiratory responses to exercise

D. H. Pearce, H. T. Milhorn Jr, G. H. Holloman and W. J. Reynolds

A computer-based system for the determination of tidal volume, respiratory frequency, minute ventilation, oxygen transfer, carbon dioxide transfer, respiratory exchange ratio, end-tidal oxygen, end-tidal carbon dioxide, and heart rate is presented. These variables are first determined on a breath-by-breath basis from data (expired carbon dioxide and oxygen fractions, airflow, and ECG) prerecorded on an FM magnetic type system. The breath-by-breath data are then averaged for each experimental run in 5-s increments. The 5-s increment data from a group of subjects can then be averaged and the SEM determined at prescribed periods of time. For the study of individual respiratory transient we found the 5-s increment data to be more useful than the breath-by-breath data because it has a lesser degree of fluctuation. The system is especially adapted to careful observation of the responses within the first few seconds of a change in work load. Appropriate computer programs are discussed. The results of several experiments are compared with data from other sources and found to be in good agreement.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
Y. Tang, M. J. Turner, J. S. Yem, and A. B. Baker
Calibration of pneumotachographs using a calibrated syringe
J Appl Physiol, August 1, 2003; 95(2): 571 - 576.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online