Journal of Applied Physiology Watch the video to see how APS reaches out to developing nations.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 42: 531-536, 1977;
8750-7587/77 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Folinsbee, L. J.
Right arrow Articles by Shepard, R. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Folinsbee, L. J.
Right arrow Articles by Shepard, R. J.

Journal of Applied Physiology, Vol 42, Issue 4 531-536, Copyright © 1977 by American Physiological Society


ARTICLES

Decrease of maximum work performance following ozone exposure

L. J. Folinsbee, F. Silverman and R. J. Shepard

A bicycle ergometer was used to measure maximum exercise oxygen consumption following 2 h of intermittent exercise in an environmental chamber ventilated with air (FA test) or filtered air plus 0.75 ppm ozone (PO test). Thirteen adult males performed both tests according to a random sequence. The maximum attained VO2 declined 10% (P less than 0.01), maximum attained work load was reduced by 10% (P less than 0.01), maximum ventilation decreased 16% (P less than 0.01), and maximum heart rate dropped 6% (P less than 0.05) in the PO test. At the highest common work load, heart rate and oxygen consumption were similar and ventilation was slightly higher (P less than 0.05); however, frequency of respiration increased 45% (P less than 0.01) and tidal voluem fell by 29% (P less than 0.01) following ozone exposure. During maximum exercise, the respiratory frequency was similar in both tests, but tidal volume was 21% lower (P less than 0.01) in PO experiments. Decreases in vital capacity and FEV1.0 as well as cough and chest discomfort were also noted following ozone exposure. We conclude that the reduction of maximum attained VO2 is a consequence of ventilatory limitation of maximum effort, probably related to respiratory discomfort.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
C.-Y. Chen, A. C. Bonham, C. G. Plopper, and J. P. Joad
Plasticity in Respiratory Motor Control: Selected Contribution: Neuroplasticity in nucleus tractus solitarius neurons after episodic ozone exposure in infant primates
J Appl Physiol, February 1, 2003; 94(2): 819 - 827.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
H. GONG Jr., R. WONG, R. J. SARMA, W. S. LINN, E. D. SULLIVAN, D. A. SHAMOO, K. R. ANDERSON, and S. B. PRASAD
Cardiovascular Effects of Ozone Exposure in Human Volunteers
Am. J. Respir. Crit. Care Med., August 1, 1998; 158(2): 538 - 546.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online