Journal of Applied Physiology, Vol 41, Issue 3 328-331, Copyright © 1976 by American Physiological Society
ARTICLES |
P. B. Taylor and F. J. Cerny
Ventricular performance and coronary flow in Langendorff perfused rat hearts were measured over a wide range of perfusion pressures and heart rates. A change in aortic pressure from 60 to 120 mmHg induced a linear increase in coronary flow, ventricular systolic pressure, and contractility. Ventricular pacing from 300 to 600 beats/min under a constant afterload had no effect on coronary flow. Systolic pressure remained stable up to 400-450 beats/min and then decreased 14% at 600 beats/min compared to the nonpaced controls. When contraction rate exceeded 450 beats/min diastolic pressure progressively increased as the heart rate was elevated. Contractility decreased rapidly between 450 and 600 beats/min under all perfusion pressures. These data indicate that this heart model is physiologically stable with heart rates less than 450 beats/min and may be useful in studying tachycardia-induced work overload.
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |