Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 40: 971-975, 1976;
8750-7587/76 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Grassino, A. E.
Right arrow Articles by Milic-Emili, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Grassino, A. E.
Right arrow Articles by Milic-Emili, J.

Journal of Applied Physiology, Vol 40, Issue 6 971-975, Copyright © 1976 by American Physiological Society


ARTICLES

Influence of lung volume and electrode position on electromyography of the diaphragm

A. E. Grassino, W. A. Whitelaw and J. Milic-Emili

In cats anesthetized with Nembutal, electromyograms of the diaphragm (Edi) were recorded from an anchored esophageal electrode, a pair of silver hooks inserted in the paratendinous region, and a pair of silver hooks and a pair of clips of small surface inserted in the costal region of the diaphragm facing the rib cage at FRC but covered with lung tissue at FRC + 80 ml. When single supramaximal electrical stimuli were applied to an isolated phrenic nerve, changes in lung volume from RV to near TLC had a negligible effect on muscle potentials from esophageal or paratendinous hooks, but increased the amplitude of potentials recorded from peripheral hooks and clips. In addition, it was found that small displacements of the esophageal electrode caused substantial changes in the amplitude of the recorded muscle potentials. The integration of the Edi spontaneously generated during occluded inspirations, recorded from paratendinous hooks and the esophageal electrode was linearly related to transdiaphragmatic pressure up to 50 cmH2O at all lung volumes. Above that level, esophageal electrode recordings showed a curvilinear Edi/Pdi relationship, while hook recordings showed a rectilinear relationship.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
ATS/ERS Statement on Respiratory Muscle Testing
Am. J. Respir. Crit. Care Med., August 15, 2002; 166(4): 518 - 624.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
Y. M. Luo, N. Hart, N. Mustfa, R. A. Lyall, M. I. Polkey, and J. Moxham
Effect of diaphragm fatigue on neural respiratory drive
J Appl Physiol, May 1, 2001; 90(5): 1691 - 1699.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. E. Butler, D. K. McKenzie, and S. C. Gandevia
Discharge frequencies of single motor units in human diaphragm and parasternal muscles in lying and standing
J Appl Physiol, January 1, 2001; 90(1): 147 - 154.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online