Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 40: 849-853, 1976;
8750-7587/76 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Walsh, G. M.
Right arrow Articles by Frohlich, E. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Walsh, G. M.
Right arrow Articles by Frohlich, E. D.

Journal of Applied Physiology, Vol 40, Issue 5 849-853, Copyright © 1976 by American Physiological Society


ARTICLES

Direct Fick application for measurement of cardiac output in rat

G. M. Walsh, M. Tsuchiya and E. D. Frohlich

The direct Fick procedure for cardiac output determination in rat was validated by simultaneous comparison with electromagnetic flowmeter techniques. Significant coefficients of correlation were obtained between absolute cardiac output values (r = 0.789, P less than 0.001), increases (r = 0.768, P less than 0.001) and decreases (r = 0.672, P less than 0.01) in cardiac output detected by the two methods. As demonstrated in other species, cardiac output values of the Fick procedure in the rat were between 40 and 58% greater than respective electromagnetic flow probe values; however, percent changes in cardiac output obtained by the two methods were similar. The larger values of cardiac output obtained by the direct Fick method may be related, to a great extent, to the distribution of blood flow to the coronary and bronchial circulations. Fick cardiac output measurements were reproducible within rats, and the degree of variation in values among rats was similar to that obtained with the flowmeter procedure. The result indicate that the Fick meth od provides a valid estimation of cardiac output in the rat, with the ability to detect moderate changes (22-36%) in cardiac output.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. Slama, D. Susic, J. Varagic, J. Ahn, and E. D. Frohlich
Echocardiographic measurement of cardiac output in rats
Am J Physiol Heart Circ Physiol, February 1, 2003; 284(2): H691 - H697.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
N. Veal, F. Moal, J. Wang, E. Vuillemin, F. Oberti, E. Roy, M. Kaassis, R. Trouve, J.-L. Saumet, and P. Cales
New method of cardiac output measurement using ultrasound velocity dilution in rats
J Appl Physiol, September 1, 2001; 91(3): 1274 - 1282.
[Abstract] [Full Text] [PDF]


Home page
ANGIOLOGYHome page
S. G. Chrysant, G. M. Walsh, E. D. Frohlich, and S. M. Townsend
Hemodynamic Changes Induced by Prolonged NaCl and DOCA Administration in Spontaneously Hypertensive Rats
Angiology, April 1, 1978; 29(4): 303 - 309.
[PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online