Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 40: 819-823, 1976;
8750-7587/76 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Traystman, R. J.
Right arrow Articles by Menkes, H. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Traystman, R. J.
Right arrow Articles by Menkes, H. A.

Journal of Applied Physiology, Vol 40, Issue 5 819-823, Copyright © 1976 by American Physiological Society


ARTICLES

Local regulation of collateral ventilation by oxygen and carbon dioxide

R. J. Traystman, G. K. Batra and H. A. Menkes

The effects of changes in CO2 and O2 on the mechanics of collateral ventilation were studied in anesthetized paralyzed dogs. A doublelumen catheter was wedged into a peripheral airway obstructing a segment of lung distal to the catheter. Through one lumen of the catheter, air, 5% CO2 in air, 10% CO2 in air, 5% O2 in N2, or 5% CO2 in N2 was infused at a constant flow (V). Pressure (Ps) was monitored through the other lumen. At functional residual capacity the resistance to collateral flor Rcoll = Ps/V. When V was interrrupted , the time for Ps to fall 63% was defined as the time constant for collateral ventilation, Tcoll. The effective compliance (Cs') = Tcoll/Rcoll. When air was replaced by 5% CO2, Rcoll fell 46.3% (+/- SE 2.8) and Tcoll fell 41.5% (+/- SE 3.0). When the CO2 concentration was increased from 5% to 10%, Rcoll fell an additional 9.2% (+/- SE 2.2) and Tcoll fell an additional 5.1% (+/- SE 4.4). When air was replaced by 5% O2 in N2, Rcoll rose 36.6% (+/- SE 6.0) and Tcoll rose 13.6% (+/- SE 10.5). No significant changes in Cs' were noted. We conclude that varying concentrations of CO2 and O2 provide potent mechanisms for the control of collateral ventillation which may be of importance in the regulation of ventillation perfusion relationships at the local level.


This article has been cited by other articles:


Home page
ChestHome page
N. Stocchetti, A. I.R. Maas, A. Chieregato, and A. A. van der Plas
Hyperventilation in Head Injury: A Review
Chest, May 1, 2005; 127(5): 1812 - 1827.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
B. A. Simon, P. B. Zanaboni, and D. P. Nyhan
Effect of hypoxia on respiratory system impedance in dogs
J Appl Physiol, August 1, 1997; 83(2): 451 - 458.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
B. A. Simon, K. Tsuzaki, and J. G. Venegas
Changes in regional lung mechanics and ventilation distribution after unilateral pulmonary artery occlusion
J Appl Physiol, March 1, 1997; 82(3): 882 - 891.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online