Journal of Applied Physiology Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 40: 625-629, 1976;
8750-7587/76 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Coon, R. L.
Right arrow Articles by Kampine, J. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Coon, R. L.
Right arrow Articles by Kampine, J. P.

Journal of Applied Physiology, Vol 40, Issue 4 625-629, Copyright © 1976 by American Physiological Society


ARTICLES

Evaluation of a dual-function pH and PCO2 in vivo sensor

R. L. Coon, N. C. Lai and J. P. Kampine

A newly developed, dual-function pH and PCO2 sensor was evaluated in this study. The sensors were placed in the femoral arteries of dogs anesthetized with sodium pentobarbital. Comparisons were made between systemic arterial pH and PCO2 measured using the sensor and those measured from blood samples drawn at 15-min intervals over a 7-h period using a bench instrument. The mean pH of the bench instrument measurements was 7.43. The mean difference of the sensor measurements from the bench instrument measurements for 207 comparisons was 0.0003 pH +/- 0.061 SD. The mean PCO2 of the bench instrument measurements was 40 mmHg. The mean difference of the sensor measurements from those of the bench instrument for 212 comparisons was -1.43 mmHg +/- 5.17 SD. The sensors performed equally well in the presence of metabolic or respiratory acidosis and alkalosis. The dual-function sensors evaluated in this study are useful for trend monitoring of pH and PCO2 over at least a 7-h period without recalibration. With improvement in the consistency of sensor construction, these sensors will be reliable in vivo sensing devices for blood pH and PCO2 and thus valuable research and clinical instruments.


This article has been cited by other articles:


Home page
ScienceHome page
C. Liu, D. Bocchicchio, P. Overmyer, and M. Neuman
A Palladium-palladium oxide miniature pH electrode
Science, January 11, 1980; 207(4427): 188 - 189.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online