Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 40: 305-311, 1976;
8750-7587/76 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Frazier, A. R.
Right arrow Articles by Hyatt, R. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Frazier, A. R.
Right arrow Articles by Hyatt, R. E.

Journal of Applied Physiology, Vol 40, Issue 3 305-311, Copyright © 1976 by American Physiological Society


ARTICLES

Single-breath oxygen tests for individual lungs in awake man

A. R. Frazier, K. Rehder, A. D. Sessler, J. R. Rodarte and R. E. Hyatt

Single-breath oxygen (SBO2) tests for individual lungs were performed in five healthy awake volunteers. In the supine position, all subjects consistently showed a closing volume (CV) for both lungs. In the lateral position, CV was demonstrated in all analyzable SBO2 tests for the dependent and in 20 of 28 for the nondependent lung. CV consistently occurred in the dependent before it occurred in the nondependent lung (asynchronous onset of CV). After CV had been reached in the nondependent lung, a mean of 77 ml of gas was still expired from the dependent lung. No changes in CV for individual lungs were demonstrated with changes in body position. Expiratory flow limitation consistently occurred first in the dependent lung (asynchronous onset of flow limitation). In the lateral position, at high lung volumes, the dependent lung achieved higher flow rates; later in expiration, the nondependent lung contributed progressively more gas to the total expirate (asynchronous emptying). In general, our findings are consistent with both the "asynchronous flow limitation" and the "airway closure" interpretations of CV. However, some of the results are not consistent with either theory.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
M. J. Rodriguez-Nieto, G. Peces-Barba, N. G. Mangado, S. Verbanck, and M. Paiva
Single-breath washouts in a rotating stretcher
J Appl Physiol, April 1, 2001; 90(4): 1415 - 1423.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online