Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 39: 697-701, 1975;
8750-7587/75 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Goldstein, I.
Right arrow Articles by Anthonisen, N. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goldstein, I.
Right arrow Articles by Anthonisen, N. R.

Journal of Applied Physiology, Vol 39, Issue 5 697-701, Copyright © 1975 by American Physiological Society


ARTICLES

Effects of expiratory threshold loading during steady-state exercise

I. Goldstein, S. Goldstein, J. A. Urbanetti and N. R. Anthonisen

Increases in functional residual capacity (FRC) decrease inspiratory muscle efficiency; the present experiments were designed to determine the effect of FRC change on the ventilatory response to exercise. Six well-trained adults were exposed to expiratory threshold loads (ETL) ranging from 5 to 40 cmH2O during steady-state exercise on a bicycle ergometer at 40-95% VO2max. Inspiratory capacity (IC) was measured and changes of IC interpreted as changes of FRC. ETL did not consistently limit exercise performance. At heavy work (greater than 92% VO2max) minute ventilation decreased with increasing ETL; at moderate work (less than 58% VO2max) it did not. Decreases in ventilation were due to decreases in respiratory frequency with prolongation of the duration of expiration being the most consistent change in breathing pattern. At moderate work levels, FRC increased with ETL; at maximum work it did not. Changes in FRC were dictated by constancy of tidal volume and a fixed maximum end-inspiratory volume of 80-90% of the inspiratory capacity. When tidal volume was such that end-inspiratory volume was less than this value, FRC increased with ETL. Mouth pressure measured during the first 0-1 s of inspiratory effort against an occluded airway (P0-1) was increased by ETL equals 30 cmH2O, in spite of the fact that ventilation was decreased. We concluded that changes in FRC due to ETL had no effect on the ventilatory response to exercise and that changes in P0-1 induced by ETL did not reflect changes of inspiratory drive so much as changes of the pattern of inspiration.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
K. N. Stark-Leyva, K. C. Beck, and B. D. Johnson
Influence of expiratory loading and hyperinflation on cardiac output during exercise
J Appl Physiol, May 1, 2004; 96(5): 1920 - 1927.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
L. L. Fee, R. M. Smith, and M. B. English
Enhanced ventilatory and exercise performance in athletes with slight expiratory resistive loading
J Appl Physiol, August 1, 1997; 83(2): 503 - 510.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
R. PELLEGRINO, J. R. RODARTE, A. E. FROST, and M. B. REID
Breathing by Double-Lung Recipients during Exercise . Response to Expiratory Threshold Loading
Am. J. Respir. Crit. Care Med., January 1, 1997; 157(1): 106 - 110.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online