Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 39: 341-348, 1975;
8750-7587/75 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Guyatt, A. R.
Right arrow Articles by Flenley, D. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Guyatt, A. R.
Right arrow Articles by Flenley, D. C.

Journal of Applied Physiology, Vol 39, Issue 3 341-348, Copyright © 1975 by American Physiological Society


ARTICLES

Reproducibility of dynamic compliance and flow-volume curves in normal man

A. R. Guyatt, J. A. Siddorn, H. M. Brash and D. C. Flenley

To evaluate methods proposed for the early detection of small airways obstruction. we have compared the precision of the forced expiratory flow-volume curve and of measurements of the frequency dependence of lung compliance in normal subjects, in 10 of whom these measurements were made on four occasions, and in 5 on two occasions. The maximal expiratory flow rate was highly reproducible, revealing consistent differences between these normal subjects, particularly when measured at 60% of TLC and corrected for differences in body size. The frequency-dependence measurements, expressed as the slope of the regression line relating dynamic compliance to frequency, showed much greater variation between repeated measurements in the same subject. Comparison with earlier published accounts is difficult in view of lack of quantitative data, but the variability between single measurements on different normal subjects appears to be similar to that which we have found when the results are expressed in a comparable manner. Dynamic compliance at a frequency of 1 Hz lay between 48% and 141% of the value obtained by extrapolation to zero frequency.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
R. ARENS, J. M. MCDONOUGH, H. ZHAO, N. P. BLUMENTHAL, R. M. KOTLOFF, and M. M. GRUNSTEIN
Altered Lung Mechanics after Double-Lung Transplantation
Am. J. Respir. Crit. Care Med., November 1, 1998; 158(5): 1403 - 1409.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online