Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 38: 1057-1061, 1975;
8750-7587/75 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bissonnette, J. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bissonnette, J. M.

Journal of Applied Physiology, Vol 38, Issue 6 1057-1061, Copyright © 1975 by American Physiological Society


ARTICLES

Control of vascular volume in sheep umbilical circulation

J. M. Bissonnette

Vascular and extravascular volumes were measured using a single-injection, double-indicator technique, in a perfused umbilical circulation in which umbilical artery (Pfa) and umbilical vein (Pfv) pressures could be independently varied. At constant Pfv, when Pfa was raised from 25 to 35 mmHg, vascular volume increased 16.1 plus or minus 6 ml (mean plus or minus SD) from a control value of 113 plus or minus 38.3 ml. Extravascular volume increased 25.2 plus or minus 7.7 ml from 128 plus or minus 53.3 ml. During further increases in Pfa to 65 mmHg, vascular volume increased approximately 10 ml for each 10 mm Hg increment, but no change in extravascular volume occurred. At a constant Pfa when Pfv was raised to 15, 20, and 25 mmHg, vascular volume increased 12.2 plus or minus 3.6, 22.2 plus or minus 5.4, and 28 plus or minus 12.5 ml from the measurements at low Pfv. There was no increase in extravascular volume during elevation of Pfv. At the lower values of Pfa (25-35 mmHg) recruitment of previously unperfused channels and distension are seen. Over the higher ranges of Pfa change and during Pfv elevation there is distension of vascular bed.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
R. S. Assad, F. Y. Lee, and F. L. Hanley
Placental compliance during fetal extracorporeal circulation
J Appl Physiol, May 1, 2001; 90(5): 1882 - 1886.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online