Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 38: 937-941, 1975;
8750-7587/75 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ott, C. E.
Right arrow Articles by Knox, F. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ott, C. E.
Right arrow Articles by Knox, F. G.

Journal of Applied Physiology, Vol 38, Issue 5 937-941, Copyright © 1975 by American Physiological Society


ARTICLES

Measurement of renal interstitial fluid pressure with polyethylene matrix capsules

C. E. Ott, J. L. Cuche and F. G. Knox

The renal interstitial fluid pressure was measured in dogs from small chronically implanted solid capsules made of porous polyethylene matrix material (pore size approximately 60 mum). Tissue does not grow into the polyethylene and the matrix creates a permanent fluid-filled space in communication with the interstitium. The fluid pressure in the capsule matrix was measured from a tube leading from the capsule with an active servo-null pressure-measuring device. Renal interstitial fluid pressure measured from 28 hydropenic dogs averaged 6.1 plus or minus 0.51 mmHg (SE). Increasing oncotic pressure inside the capsule to 90 mmHg resulted in a small but significant increase in hydrostatic pressure inside the capsule of 3.3 plus or minus 0.46 mmHg. However, the hydrostatic pressure returned to control levels within 30 min. In vitro studies indicated that the pressure measured from the capsule was highly sensitive to change in surrounding hydrostatic pressure, but insensitive to change in surrounding oncotic pressure. Histological studies showed a small layer of connective tissue surrounding the capsule less than 100 mum thick in many areas. There was no evidence of inflammation or tissue rejection. It is concluded that the small chronically implanted polyethylene capsule is a reliable method for the measurement of renal interstitial fluid pressure.


This article has been cited by other articles:


Home page
HypertensionHome page
S. Kassab, J. Novak, T. Miller, K. Kirchner, and J. Granger
Role of Endothelin in Mediating the Attenuated Renal Hemodynamics in Dahl Salt-Sensitive Hypertension
Hypertension, September 1, 1997; 30(3): 682 - 686.
[Abstract] [Full Text]


Home page
HypertensionHome page
T. Kato, S. Kassab, F. C. Wilkins Jr, K. A. Kirchner, J. Keiser, and J. P. Granger
Endothelin Antagonists Improve Renal Function in Spontaneously Hypertensive Rats
Hypertension, April 1, 1995; 25(4): 883 - 887.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online