Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 38: 427-435, 1975;
8750-7587/75 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bobbaers, H.
Right arrow Articles by Woestijne, K. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bobbaers, H.
Right arrow Articles by Woestijne, K. P.

Journal of Applied Physiology, Vol 38, Issue 3 427-435, Copyright © 1975 by American Physiological Society


ARTICLES

Simulation of frequency dependence of compliance and resistance in healthy man

H. Bobbaers, J. Clement, J. Pardaens and K. P. Woestijne

The frequency dependence of effective compliance, Ceff, and resistance, Reff, are reproduced by means of a two- or four-compartment linear mathematical model with pleural pressure as a sinusoidal input. The model simulates the mechanical properties of lung parenchyma, alveolar gas, bronchial wall, and cheeks, as well as the distribution of gaseous resistances and inertances within the airways. Values, representative for a young healthy adult, are assigned to these various parametersmit appears from this study: 1) that the gas inertance produces a very marked increase of Ceff, noticeable already below 1 cycle/smto obtain a frequency independence of Ceff between 0 and 2 cycles/s, it is necessary to introduce a marked inhomogeneity in the model. 2) Such an inhomogeneity is realized by simulating a pleural pressure difference of 6 cmH2O between the compartments of the bialveolar model. It can be shown that this corresponds to a total pleural pressure difference of about 9 cmH2O in a model consisting of an infinite number of compartments. 3) The influence of the compressibility of alveolar gas and of mechanical properties of the bronchial wall and of the cheeks on Ceff and Reff is small or negligible.