Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 38: 344-350, 1975;
8750-7587/75 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gow, B. S.
Right arrow Articles by Vaishnav, R. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gow, B. S.
Right arrow Articles by Vaishnav, R. N.

Journal of Applied Physiology, Vol 38, Issue 2 344-350, Copyright © 1975 by American Physiological Society


ARTICLES

A microindentation technique to measure rheological properties of the vascular intima

B. S. Gow and R. N. Vaishnav

A microindentor was developed to measure the depth of indentation of the intimal surface of arterial tissue loaded by flat-ended, cylindrical probes. The depth of indentation depended on the initial stretch of the tissue which required a rigid support (plaster of Paris) beneath the adventitial surface. Probe tips used ranged from 550-mum down to 65-mum diameter while loads ranged from 800 to 15 mg. The depth of indentation was markedly time dependent; that obtained 30 s after loading (variation of 30) was reproducible and served as a useful parameter of viscoelasticity of the aortic intima and supporting tissues of dog and man. The mean variation of 30 (0.19-mm diam tip, 120-mg load), obtained from longitudinal series of indentations of nine dog aortas, ranged from 40.8 to 68.8 mum while coefficient of variation in these series ranged from 4.8 to 15.9%. Intimal pads were found to have greater resistance to identation than adjacent tissue; likewise the tissue on the dorsal, intimal surface of the aorta had lower variation of 30 values compared with the rest of the intima. Lipid-filled intimal regions were about twice as complaint as macroscopically spared areas. The technique should prove useful in understanding the microrheological response of the blood vascular interface to hydrodynamic stresses.