Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 38: 328-334, 1975;
8750-7587/75 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Saidel, G. M.
Right arrow Articles by Chester, E. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Saidel, G. M.
Right arrow Articles by Chester, E. H.

Journal of Applied Physiology, Vol 38, Issue 2 328-334, Copyright © 1975 by American Physiological Society


ARTICLES

Moment analysis of multibreath lung washout

G. M. Saidel, R. B. Salmon and E. H. Chester

A moment analysis of multibreath nitrogen washout has been developed to provide a sensitive, quantitative measure that characterizes the inhomogeneity of pulmonary ventilation. To test the analysis scheme, we studied 5 normal subjects and 16 subjects with obstructive lung disease who performed each washout test at constant tidal volume and frequency. Subjects executed the wahout test 3-4 times at different tidal volumes (0.5-1.5 liters) and frequencies (10-30/min). Plotting washout data as dimensionless end-tidal nitrogen concentration versus the cumulative expired volume normalized by the functional residual capacity (CEV/FRC) renders the washout curves of each individual almost superposab le despite changes in breathing frequency and tidal volume from test to test. The dimensionless washout curve is treated as a distribution from which the normalized first (M1/Mo) and second (M2/Mo) moments are obtained. These parameters clearly display diagnostic clustering for various disease states. With respect to the normal subjects, the magnitude of M1/Mo was 26% greater for asthmatics, 38% greater for bronchitics, and 52% greater for emphysematics. This moment analysis provides an objective, quantitative assessment of the extent of ventilation inhomogeneities without specification of a lung model.


This article has been cited by other articles:


Home page
ThoraxHome page
P. Latzin, C. Thamrin, and R. Kraemer
Ventilation inhomogeneities assessed by the multibreath washout (MBW) technique
Thorax, February 1, 2008; 63(2): 98 - 99.
[Full Text] [PDF]


Home page
Br J AnaesthHome page
J. S. Yem, M. J. Turner, and A. B. Baker
Sources of error in partial rebreathing pulmonary blood flow measurements in lungs with emphysema and pulmonary embolism
Br. J. Anaesth., November 1, 2006; 97(5): 732 - 741.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
J. S. Yem, M. J. Turner, A. B. Baker, I. H. Young, and A. B. H. Crawford
A tidally breathing model of ventilation, perfusion and volume in normal and diseased lungs
Br. J. Anaesth., November 1, 2006; 97(5): 718 - 731.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online