Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 38: 199-207, 1975;
8750-7587/75 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Begin, R.
Right arrow Articles by Watanabe, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Begin, R.
Right arrow Articles by Watanabe, S.

Journal of Applied Physiology, Vol 38, Issue 2 199-207, Copyright © 1975 by American Physiological Society


ARTICLES

Flow and age dependence of airway closure and dynamic compliance

R. Begin, A. D. Renzetti Jr, A. H. Bigler and S. Watanabe

The influence of expiratory flow rate and age on the results of measurement of closing volume (CV) of the lung have been studied by a nitrogen single-breath method in 66 asymptomatic lifetime nonsmoking normal subjects between 20 and 82 yr of age. Normal was defined as having values for spirometric measurements within a 95% tolerance interval of reported predicted normal mean values. For the CV determination, inspiratory flow rate was held constant at 0.51/s and studies were carried out at expiratory flow rates of 0.25, 0.5, 1.0, and 1.5 1/s. Our results show that CV expressed as a percentage of vital capacity (VC) and the slope of the alveolar plateau increases with increasing flow rate and age. Dynamic compliance (Cdyn) at frequencies corresponding to peak flow rates of 0.5 and 1.5 1/s was also measured and correlated well with the CV results. Frequency dependence of compliance with aging was demonstrated. Nine smokers with normal spirometric measurements and abnormal CV %VC were also studied. Since the results of Cdyn measurement differentiated only two-thirds of the smokers from the normal population, we suggest that the CV method is probably more sensitive than the Cdyn method for the detection of small airway obstruction.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
V. GROSS, A. DITTMAR, T. PENZEL, F. SCHÜTTLER, and P. von WICHERT
The Relationship between Normal Lung Sounds, Age, and Gender
Am. J. Respir. Crit. Care Med., September 1, 2000; 162(3): 905 - 909.
[Abstract] [Full Text]


Home page
Am. J. Respir. Crit. Care Med.Home page
R. D. YUSEN, A. H. COHEN, and A. HAMVAS
Normal Lung Function in Subjects Heterozygous for Surfactant Protein-B Deficiency
Am. J. Respir. Crit. Care Med., February 1, 1999; 159(2): 411 - 414.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online