Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 38: 177-180, 1975;
8750-7587/75 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zabinski, M. P.
Right arrow Articles by Biancani, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zabinski, M. P.
Right arrow Articles by Biancani, P.

Journal of Applied Physiology, Vol 38, Issue 1 177-180, Copyright © 1975 by American Physiological Society


ARTICLES

Influence of perfusion rate and compliance on esophageal manometry

M. P. Zabinski, H. M. Spiro and P. Biancani

The accuracy of esophageal manometry using the conventional perfused three-lumen catheter depends on the proper choice of the perfusion rate. Previous investigators have used a wide range of perfusion rates without considering the compliance of the transducer-catheter assembly as a variable in the selection of the perfusion rate for the hydraulic systems. We present a relationship relating the perfusion rate and the compliance which specifies the minimum adequate perfusion rate for a given transducer-catheter assembly. This approach explains apparent discrepancies in the literature regarding the proper rate of perfusion for accurate measurement of esophageal contractions. Esophageal motility tests with 10 subjects confirmed the accuracy of manometric tests at the prescribed perfusion rate (1.25 ml/min) since they compared well with intraluminal pressures measured directly with a Honeywell intraesophageal transducer. The effect of perfusion rate on the apmlitude of esophageal contraction was also investigated and it is shown that high perfusion rates result in increased amplitudes of contraction. Furthermore, at large perfusion rates a large volume of liquid builds up in the esophagus. This fluid accumulation could possibly be responsible for the increased amplitudes of contraction.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online