Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 20: 696-702, 1965;
8750-7587/65 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wright, H. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wright, H. M.

Measurement of the cutaneous circulation

Harry M. Wright 1

1 Department of Physiology, Kirksville College of Osteopathy and Surgery, Kirksville, Missouri

Relationships between four commonly used indirect methods for study of the cutaneous circulation in intact, unanesthetized man were examined. Skin temperature, thermal conductance, volume plethysmography and the light absorption of the skin (as related to hemoglobin content) were simultaneously recorded on the upper extremities of normal young men as blood flow and blood content of the skin were changed by circulatory arrest, venous occlusion, indirect heating and cooling, and changes in position. Skin temperature and thermal conductance changed along parallel courses as blood flow was changed, while finger volume and reflectance of the skin to light of wavelength 550 mµ both changed in expected directions although along different courses, following passive congestion and de-congestion and changes in level of the hand relative to the heart. The advantages, disadvantages, and limitations of each of the methods in the study of cutaneous circulation in man are discussed and compared.

measurement of circulation of skin; methods for measurement of cutaneous circulation; blood flow through skin; blood content of skin; skin

Submitted on March 12, 1964




This article has been cited by other articles:


Home page
ScienceHome page
R. F. Rushmer, K. J. K. Buettner, J. M. Short, and G. F. Odland
The Skin
Science, October 21, 1966; 154(3747): 343 - 348.
[PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online