Journal of Applied Physiology Add DOIs to your references at manuscript stage!
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 19: 59-74, 1964;
8750-7587/64 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sølvsteen, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sølvsteen, P.

Measurement of lung diffusing capacity by means of C14O in a closed system

Paul Sølvsteen 1

1 Medical Department and Department of Epidemiology, Blegdamshospitalet, and Institute of Medical Physiology, University of Copenhagen, Copenhagen, Denmark

A method of measuring the lung diffusing capacity (Dl) with radioactive carbon monoxide (C14O) and nonuniformity of ventilation with nonabsorbable gas in a closed system is described. Treating ventilation as a continuous phenomenon and disregarding dead space, the mathematical equations for uniform and nonuniform ventilation (two lung regions ventilated in parallel) are derived. It is proved that sooner or later the curve for carbon monoxide, plotted on semilogarithmic paper, will be rectilinear. Experiments in six normal subjects and eight patients with chronic lung disease are described. Determinations of the distribution of the ventilation and the Dl are made in separate experiments. Since the method is unreliable at high Dl values, many of the Dl estimations are performed at high oxygen tension, which reduces the apparent Dl. It is shown that the assumption of a uniform distribution of Dl to lung volume explains the experimental findings better than the assumption of a uniform distribution of Dl to alveolar ventilation. Dl was decreased in four of the eight patients.

mathematics of uniform and nonuniform ventilation; distribution of lung diffusing capacity in relation to lung volume and alveolar ventilation; N2 curve for use in calculating alveolar ventilation and regional lung volumes; CO curve for use in calculating lung diffusing capacity; diffusing capacity of lung determined with a closed system

Submitted on October 15, 1962







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online