Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 18: 1252-1256, 1963;
8750-7587/63 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Boling, E. A.
Right arrow Articles by Lipkind, J. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Boling, E. A.
Right arrow Articles by Lipkind, J. B.

Simultaneous assay of K42, Na24, and Br82 in body composition measurements

E. A. Boling 1, E. Rossmeisl 1, R. McLean 1, H. Alpert 1, R. Gardner 1, M. Halpin 1, and J. B. Lipkind 1

1 Medical Service and Research Laboratory, Boston Veterans Administration Hospital, and Department of Medicine, Tufts University School of Medicine, Boston, Massachusetts

Simultaneous measurements of Na24 and K42 specific activities may be based on chemical, physical, or metabolic differences between these two radioisotopes. This paper describes a rapid and precise technique based on both physical and metabolic differences. Two counters, a gamma-ray and a beta-ray counter, are used. Two samples are collected from each patient at tracer equilibrium (40 hr after administration of K42, 50 µc; Na24, 30 µc; Br82, 20 µc): urine, which has a high chemical K: Na ratio, and serum, which has a low chemical K: Na ratio. The urine is counted in the beta-ray counter, which favors K42. The serum is counted in the gammaray counter, which favors Na24. To calculate the specific activities, equations are used which contain appropriate decay corrections, to permit calculation of the individual specific activities even though simultaneous counting of the samples in the two detectors is not required. The laboratory procedure is simple and straightforward, and the procedure gives results which are comparable in accuracy to methods which use only one isotope at a time. When counters of great sensitivity are employed, the procedure permits both small doses of radioisotope and long equilibration periods (40 hr). Total exchangeable chloride can be estimated at the same time by Br82 dilution. The calculation has been programed for a large digital computer.

radioisotope separation; total exchangeable sodium; total exchangeable chloride; total exchangeable potassium

Submitted on September 27, 1962







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online