Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 18: 1247-1251, 1963;
8750-7587/63 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Charlton, G.
Right arrow Articles by Read, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Charlton, G.
Right arrow Articles by Read, J.

Continuous intra-arterial Po2 in normal man using a flexible microelectrode

G. Charlton 1, David Read 1, and John Read 1

1 Departments of Bacteriology and Medicine, University of Sydney, New South Wales, Australia

A flexible microelectrode, for continuous recording of blood oxygen tension, has been developed for direct insertion into small blood vessels or passage through a cardiac catheter. The design overcomes difficulties arising from pressure of the oxygen-permeable membrane against the vessel wall and greatly increases the robustness and effective life of the electrode. For routine intra-arterial use a satisfactory compromise has been achieved between speed of response (95% in 15 sec), cathode current (3 x 10–11 amp/mm Hg Po2), and freedom from "stirring" artefact (less than 3%). Serial in vitro readings of Po2 over periods of 4 hr have been reproducible (2 sd ± 3% pro rata) without recalibration. In vivo accuracy and stability have been established by continuous recording of Po2 within the brachial artery of six nonheparinized humans for periods up to 1 hr. The maximum difference observed between initial in vivo and in vitro readings was 2.5%. The reproducibility of serial washout and washin curves has been analyzed to provide an indication of in vivo stability. The technique is safe provided that the precautions outlined to prevent thromboemboli are carefully followed.

electroanalytical chemistry; polarography; respiratory physiology; oxygen tension in biological fluids

Submitted on December 26, 1962







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online