Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 16: 289-292, 1961;
8750-7587/61 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Conrad, M. C.
Right arrow Articles by Green, H. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Conrad, M. C.
Right arrow Articles by Green, H. D.

Evaluation of venous occlusion plethysmograph

Margaret C. Conrad 1 and Harold D. Green 1

1 Department of Physiology and Pharmacology, Bowman Gray School of Medicine of Wake Forest College, Winston-Salem, North Carolina

Inflow and outflow, occlusion and perfusion pressures, and pressure in a small vein in the paw were measured simultaneously with the plethysmogram on the amputated forepaws of dogs. Venous tamponade was complete for a period of time dependent on the height of occlusion pressure and the magnitude of arterial flow. Paw venous pressure rose rapidly to ‘effective occlusion pressure,’ at which time blood began to escape beneath the occlusion cuff. Arterial flow began to decline immediately after occlusion. Two occlusion artifacts were observed. The first was an abrupt deflection that could be easily avoided on the plethysmogram, and the second was a slower rise that could be detected only when inflow was interrupted prior to occlusion. The plethysmographically measured flow was not significantly different from inflow measured with the electromagnetic flowmeter because of a balance between the positive error due to artifact and the negative error due to the effect of occlusion on inflow.

Submitted on September 22, 1960




This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
K. K. McCully, S. Smith, S. Rajaei, J. S. Leigh Jr., and B. H. Natelson
Muscle metabolism with blood flow restriction in chronic fatigue syndrome
J Appl Physiol, March 1, 2004; 96(3): 871 - 878.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
G. Radegran, E. Blomstrand, and B. Saltin
Peak muscle perfusion and oxygen uptake in humans: importance of precise estimates of muscle mass
J Appl Physiol, December 1, 1999; 87(6): 2375 - 2380.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
S. Remsburg, S. H. Launois, and J. W. Weiss
Patients with obstructive sleep apnea have an abnormal peripheral vascular response to hypoxia
J Appl Physiol, September 1, 1999; 87(3): 1148 - 1153.
[Abstract] [Full Text] [PDF]


Home page
ANGIOLOGYHome page
K. Myers
The Investigation of Peripheral Arterial Disease By Strain Gauge Plethysmography
Angiology, July 1, 1964; 15(7): 293 - 304.
[PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online