Journal of Applied Physiology AJP: Lung Cellular and Molecular Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 107: 977-986, 2009. First published April 9, 2009; doi:10.1152/japplphysiol.91620.2008
8750-7587/09 $8.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
107/3/977    most recent
91620.2008v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Google Scholar
Right arrow Articles by Estenne, M.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Estenne, M.

REVIEW

HIGHLIGHTED TOPIC
The Respiratory Muscles in Chronic Obstructive Pulmonary Disease

Effect of lung transplant and volume reduction surgery on respiratory muscle function

Marc Estenne

Chest Service and Thoracic Transplantation Unit, Erasme University Hospital, Brussels School of Medicine, Brussels, Belgium

Submitted 19 December 2008 ; accepted in final form 3 April 2009

ABSTRACT

Lung transplantation and lung volume reduction surgery have opened a new therapeutic era for patients with advanced emphysema. In addition to providing impressive clinical benefits, they have helped us better understand how the chest wall and respiratory muscles adapt to chronic hyperinflation. This article reviews the effects of these procedures on respiratory muscle and chest wall function. Inspiratory (including diaphragm) and expiratory muscle strength are often close to normal after unilateral and bilateral transplantation, although some patients have marked weakness. After bilateral transplantation for emphysema, graft volume is normal at full inflation but remains greater than normal at end expiration, which results from structural changes in the chest wall. In contrast, patients with unilateral transplantation have a reduction in graft volume at full inflation. The mediastinum is displaced toward the graft at end expiration, which reduces the surface area of the diaphragm on the transplanted side, and it moves toward the native lung during tidal and full inspiration and toward the graft during tidal and forced expiration. Lung volume reduction produces an increase in contractility, length and surface area of the diaphragm, and increases its contribution to tidal volume; at the same time, neural drive to the muscle and respiratory load are reduced, such that diaphragm neuromechanical coupling is improved. Diaphragm configuration and rib cage dimensions are only minimally affected by the procedure. Single-lung transplantation and lung volume reduction favorably impact on the disadvantageous size interaction by which the lungs are functionally restricted by the chest wall in emphysema.

airflow obstruction; chest wall; transplantation; volume reduction; hyperinflation; diaphragm



Address for reprint requests and other correspondence: M. Estenne, Chest Service, Erasme Univ. Hospital, 808 route de Lennik, B-1070 Brussels, Belgium (e-mail: mestenne{at}ulb.ac.be)




This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
S. H. Loring, M. Garcia-Jacques, and A. Malhotra
Pulmonary characteristics in COPD and mechanisms of increased work of breathing
J Appl Physiol, July 1, 2009; 107(1): 309 - 314.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
A. De Troyer and M. J. Tobin
Introducing the Highlighted Topic series
J Appl Physiol, July 1, 2009; 107(1): 308 - 308.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2009 by the American Physiological Society.