Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 107: 80-89, 2009. First published May 21, 2009; doi:10.1152/japplphysiol.90322.2008
8750-7587/09 $8.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
107/1/80    most recent
90322.2008v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Google Scholar
Right arrow Articles by Altenburg, T. M.
Right arrow Articles by de Ruiter, C. J.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Altenburg, T. M.
Right arrow Articles by de Ruiter, C. J.

Vastus lateralis single motor unit EMG at the same absolute torque production at different knee angles

T. M. Altenburg,1,2 A. de Haan,1,2 P. W. L. Verdijk,2 W. van Mechelen,3 and C. J. de Ruiter2

1Institute for Biomedical Research into Human Movement and Health, Manchester Metropolitan University, Cheshire, United Kingdom; 2Research Institute MOVE, Faculty of Human Movement Sciences, VU University Amsterdam, Amsterdam, The Netherlands; and 3EMGO Institute and Department of Public and Occupational Health, VU University Medical Centre, Amsterdam, The Netherlands

Submitted 26 February 2008 ; accepted in final form 16 May 2009

Single motor unit electromyographic (EMG) activity of the knee extensors was investigated at different knee angles with subjects (n = 10) exerting the same absolute submaximal isometric torque at each angle. Measurements were made over a 20° range around the optimum angle for torque production (AngleTmax) and, where feasible, over a wider range (50°). Forty-six vastus lateralis (VL) motor units were recorded at 20.7 ± 17.9 %maximum voluntary contraction (%MVC) together with the rectified surface EMG (rsEMG) of the superficial VL muscle. Due to the lower maximal torque capacity at positions more flexed and extended than AngleTmax, single motor unit recruitment thresholds were expected to decrease and discharge rates were expected to increase at angles above and below AngleTmax. Unexpectedly, the recruitment threshold was higher (P < 0.05) at knee angles 10° more extended (43.7 ± 22.2 N·m) and not different (P > 0.05) at knee angles 10° more flexed (35.2 ± 17.9 N·m) compared with recruitment threshold at AngleTmax (41.8 ± 21.4 N·m). Also, unexpectedly the discharge rates were similar (P > 0.05) at the three angles: 11.6 ± 2.2, 11.6 ± 2.1, and 12.3 ± 2.1 Hz. Similar angle independent discharge rates were also found for 12 units (n = 5; 7.4 ± 5.4 %MVC) studied over the wider (50°) range, while recruitment threshold only decreased at more flexed angles. In conclusion, the similar recruitment threshold and discharge behavior of VL motor units during submaximal isometric torque production suggests that net motor unit activation did not change very much along the ascending limb of the knee-angle torque relationship. Several factors such as length-dependent twitch potentiation, which may contribute to this unexpected aspect of motor control, are discussed.

recruitment threshold; discharge rate; muscle length; quadriceps muscle



Address for reprint requests and other correspondence: C. J. de Ruiter, Research Institute MOVE, Faculty of Human Movement Sciences, VU Univ. Amsterdam, Van der Boechorststraat 9, 1081 BT, Amsterdam, The Netherlands (e-mail: c_j_de_ruiter{at}fbw.vu.nl)







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2009 by the American Physiological Society.