Journal of Applied Physiology AJP citation statistics
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 107: 155-160, 2009. First published May 7, 2009; doi:10.1152/japplphysiol.91657.2008
8750-7587/09 $8.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
107/1/155    most recent
91657.2008v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Google Scholar
Right arrow Articles by Lee, J.
Right arrow Articles by Galassetti, P. R.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, J.
Right arrow Articles by Galassetti, P. R.

Improved predictive models for plasma glucose estimation from multi-linear regression analysis of exhaled volatile organic compounds

Jane Lee,1 Jerry Ngo,4 Don Blake,3 Simone Meinardi,3 Andria M. Pontello,4 Robert Newcomb,4 and Pietro R. Galassetti1,2,4

Departments of 1Pharmacology, 2Pediatrics, and 3Chemistry, and 4General Clinical Research Center/Institute for Clinical Translational Science, University of California, Irvine, Orange, California

Submitted 29 December 2008 ; accepted in final form 2 May 2009

Exhaled volatile organic compounds (VOCs) represent ideal biomarkers of endogenous metabolism and could be used to noninvasively measure circulating variables, including plasma glucose. We previously demonstrated that hyperglycemia in different metabolic settings (glucose ingestion in pediatric Type 1 diabetes) is paralleled by changes in exhaled ethanol, acetone, and methyl nitrate. In this study we integrated these gas changes along with three additional VOCs (2 forms of xylene and ethylbenzene) into multi-linear regression models to predict plasma glucose profiles in 10 healthy young adults, during the 2 h following an intravenous glucose bolus (matched samples of blood, exhaled and room air were collected at 12 separate time points). The four-gas model with highest predictive accuracy estimated plasma glucose in each subject with a mean R value of 0.91 (range 0.70–0.98); increasing the number of VOCs in the model only marginally improved predictions (average R with best 5-gas model = 0.93; with 6-gas model = 0.95). While practical development of this methodology into clinically usable devices will require optimization of predictive algorithms on large-scale populations, our data prove the feasibility and potential accuracy of breath-based glucose testing.

breath analysis; exhaled gases; hyperglycemia; intravenous glucose tolerance test



Address for reprint requests and other correspondence: P. R. Galassetti, UCI GCRC-Bldg 25-2ndFloor, 101 The City Dr., Orange, CA 92868 (e-mail: pgalasse{at}uci.edu)







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2009 by the American Physiological Society.