Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 106: 1686-1691, 2009. First published March 19, 2009; doi:10.1152/japplphysiol.91519.2008
8750-7587/09 $8.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
106/5/1686    most recent
91519.2008v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chen, H. Y.
Right arrow Articles by Kassab, G. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chen, H. Y.
Right arrow Articles by Kassab, G. S.

TRANSLATIONAL PHYSIOLOGY

Effects of stent sizing on endothelial and vessel wall stress: potential mechanisms for in-stent restenosis

Henry Y. Chen,1,6 James Hermiller,2 Anjan K. Sinha,3 Michael Sturek,5,6 Luoding Zhu,4 and Ghassan S. Kassab1,5,6,7

1Weldon School of Biomedical Engineering, Purdue University, West Lafayette; 2Department of Cardiovascular Surgery, St. Vincent Hospital, Indianapolis; and Departments of 3Medicine (Cardiology), 4Mathematical Sciences, 5Surgery, 6Cellular and Integrative Physiology, and 7Biomedical Engineering, Indiana University Purdue University Indianapolis, Indianapolis, Indiana

Submitted 21 November 2008 ; accepted in final form 13 March 2009

ABSTRACT

Stent sizing and apposition have been shown to be important determinants of clinical outcome. This study evaluates the mechanical effects of undersizing and oversizing of stents on endothelial wall shear stress (WSS) and vessel wall stress to determine a possible biomechanical mechanism of in-stent restenosis and thrombosis. Three-dimensional computational models of stents, artery, and internal fluid were created in a computer-assisted design package, meshed, and solved in finite element and computational fluid dynamic packages. The simulation results show that the effects of various degrees of undersizing on WSS, WSS gradient, and oscillatory shear index were highly nonlinear. As the degree of undersizing increased, the heterogeneity of WSS became smaller. The WSS distribution for the 20% undersizing was smooth and uniform, whereas the 5% case was very heterogeneous. The combination of lower WSS and higher WSS gradient and oscillatory shear index in the 5% undersized case may induce neointimal hyperplasia or thrombosis. Additionally, the oversizing simulation results show that the maximum intramural wall stress of the 20% oversizing case is significantly larger than the maximum stress for the 10% and zero oversizing cases. Edge stress concentration was observed, consistent with the restenosis typically observed in this region. This study demonstrates that proper sizing of stent is important for reducing the hemodynamic and mechanical disturbances to the vessel wall. Furthermore, the present findings may be used to improve stent design to reduce endothelial flow disturbances and intramural wall stress concentrations.

undersizing; oversizing; intimial hyperplasia; shear stress



Address for reprint requests and other correspondence: G. S. Kassab, Indiana Univ. Purdue Univ. Indianapolis, Biomedical Engineering, SL-174, 723 West Michigan St., Indianapolis, Indiana 46202







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2009 by the American Physiological Society.