Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 106: 640-650, 2009. First published November 13, 2008; doi:10.1152/japplphysiol.90718.2008
8750-7587/09 $8.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Supplemental Tables
Right arrow All Versions of this Article:
106/2/640    most recent
90718.2008v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tokuyama, K.
Right arrow Articles by Satoh, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tokuyama, K.
Right arrow Articles by Satoh, M.

INNOVATIVE METHODOLOGY

INNOVATIVE METHODOLOGIES

Algorithm for transient response of whole body indirect calorimeter: deconvolution with a regularization parameter

Kumpei Tokuyama,1 Hitomi Ogata,1 Yasuko Katayose,2 and Makoto Satoh2

1Division of Sports Medicine and 2Division of Sleep Medicine, School of Comprehensive Human Science, University of Tsukuba, Ibaraki, Japan

Submitted 4 June 2008 ; accepted in final form 11 November 2008

A whole body indirect calorimeter provides accurate measurement of energy expenditure over long periods of time, but it has limitations to assess its dynamic changes. The present study aimed to improve algorithms to compute O2 consumption and CO2 production by adopting a stochastic deconvolution method, which controls the relative weight of fidelity to the data and smoothness of the estimates. The performance of the new algorithm was compared with that of other algorithms (moving average, trends identification, Kalman filter, and Kalman smoothing) against validation tests in which energy metabolism was evaluated every 1 min. First, an in silico simulation study, rectangular or sinusoidal inputs of gradually decreasing periods (64, 32, 16, and 8 min) were applied, and samples collected from the output were corrupted with superimposed noise. Second, CO2 was infused into a chamber in gradually decreasing intervals and the CO2 production rate was estimated by algorithms. In terms of recovery, mean square error, and correlation to the known input signal in the validation tests, deconvolution performed better than the other algorithms. Finally, as a case study, the time course of energy metabolism during sleep, the stages of which were assessed by a standard polysomnogram, was measured in a whole body indirect calorimeter. Analysis of covariance revealed an association of energy expenditure with sleep stage, and energy expenditure computed by deconvolution and Kalman smoothing was more closely associated with sleep stages than that based on trends identification and the Kalman filter. The new algorithm significantly improved the transient response of the whole body indirect calorimeter.

time resolution; Kalman-Bucy method



Address for reprint requests and other correspondence: K. Tokuyama, Division of Sports Medicine, School of Comprehensive Human Science, Univ. of Tsukuba, Ibaraki, Japan 305-8574. (e-mail: tokuyama{at}taiiku.tsukuba.ac.jp)







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2009 by the American Physiological Society.