Journal of Applied Physiology Track the topics, authors and articles important to you
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 105: 711-717, 2008. First published May 1, 2008; doi:10.1152/japplphysiol.00949.2007
8750-7587/08 $8.00
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
105/2/711    most recent
00949.2007v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Reynolds, J. S.
Right arrow Articles by Frazer, D. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Reynolds, J. S.
Right arrow Articles by Frazer, D. G.

INNOVATIVE METHODOLOGY

Unrestrained acoustic plethysmograph for measuring specific airway resistance in mice

Jeffrey S. Reynolds,1 Victor J. Johnson,2 and David G. Frazer1

1Pathology and Physiology Research Branch and 2Toxicology and Molecular Biology Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, West Virginia

Submitted 6 September 2007 ; accepted in final form 25 April 2008

An acoustic whole body plethysmograph was developed to estimate specific airway resistance (sRaw) in unrestrained mice. The plethysmograph uses acoustic principles to measure the thoracic breathing pattern and simultaneously measures the airflow entering and/or leaving the plethysmograph. Similarly to traditional methods utilizing a double-chamber plethysmograph, these measurements were combined to estimate sRaw. To evaluate the new system, we placed six conscious A/J mice individually in a whole body plethysmograph (Buxco System) for a 2-min exposure to aerosolized methacholine chloride dissolved in saline (0, 5, 10, and 20 mg/ml), which is known to increase sRaw in mice. Three minutes after exposure, the mice were transferred to the acoustic plethysmograph for 2 min for data collection. The mean baseline value of sRaw was 0.93 ± 0.10 cmH2O·s. A dose-dependent increase in sRaw was shown, with an approximate tripling of sRaw at the highest dose. These results demonstrate the ability of the system to estimate sRaw based on plethysmograph airflow and acoustic amplitude.

Helmholtz resonator; unrestrained plethysmograph; whole body plethysmograph



Address for reprint requests and other correspondence: J. S. Reynolds, Pathology and Physiology Research Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, 1095 Willowdale Rd., ms L2101, Morgantown, WV 26505 (e-mail: jsr0{at}cdc.gov)




This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
W. Mitzner
Why can't mice just learn to pant?
J Appl Physiol, August 1, 2008; 105(2): 402 - 402.
[Full Text] [PDF]