Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 102: 1324-1328, 2007. First published December 28, 2006; doi:10.1152/japplphysiol.01195.2006
8750-7587/07 $8.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
102/4/1324    most recent
01195.2006v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (3)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Arieli, R.
Right arrow Articles by Abramovich, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Arieli, R.
Right arrow Articles by Abramovich, A.

Decompression sickness in the rat following a dive on trimix: recompression therapy with oxygen vs. heliox and oxygen

R. Arieli, P. Svidovsky, and A. Abramovich

Israel Naval Medical Institute, Israel Defense Forces Medical Corps, Haifa, Israel

Submitted 22 October 2006 ; accepted in final form 18 December 2006

Trimix (a mixture of helium, nitrogen, and oxygen) has been used in deep diving to reduce the risk of high-pressure nervous syndrome during compression and the time required for decompression at the end of the dive. There is no specific recompression treatment for decompression sickness (DCS) resulting from trimix diving. Our purpose was to validate a rat model of DCS on decompression from a trimix dive and to compare recompression treatment with oxygen and heliox (helium-oxygen). Rats were exposed to trimix in a hyperbaric chamber and tested for DCS while walking in a rotating wheel. We first established the experimental model, and then studied the effect of hyperbaric treatment on DCS: either hyperbaric oxygen (HBO) (1 h, 280 kPa oxygen) or heliox-HBO (0.5 h, 405 kPa heliox 50%-50% followed by 0.5 h, 280 kPa oxygen). Exposure to trimix was conducted at 1,110 kPa for 30 min, with a decompression rate of 100 kPa/min. Death and most DCS symptoms occurred during the 30-min period of walking. In contrast to humans, no permanent disability was found in the rats. Rats with a body mass of 100–150 g suffered no DCS. The risk of DCS in rats weighing 200–350 g increased linearly with body mass. Twenty-four hours after decompression, death rate was 40% in the control animals and zero in those treated immediately with HBO. When treatment was delayed by 5 min, death rate was 25 and 20% with HBO and heliox, respectively.

technical diving; helium; hyperbaric chamber



Address for reprint requests and other correspondence: R. Arieli, Israel Naval Medical Institute, POB 8040, Haifa 31080, Israel (e-mail: rarieli{at}netvision.net.il)




This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
R. Arieli, E. Boaron, and A. Abramovich
Combined effect of denucleation and denitrogenation on the risk of decompression sickness in rats
J Appl Physiol, April 1, 2009; 106(4): 1453 - 1458.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
A. Boussuges
A rat model to study decompression sickness after a trimix dive
J Appl Physiol, April 1, 2007; 102(4): 1301 - 1302.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2007 by the American Physiological Society.