Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 102: 762-771, 2007. First published November 2, 2006; doi:10.1152/japplphysiol.01139.2005
8750-7587/07 $8.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
102/2/762    most recent
01139.2005v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tsang, J. Y. C.
Right arrow Articles by Hlastala, M. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsang, J. Y. C.
Right arrow Articles by Hlastala, M. P.

Endothelin receptor blockade does not improve hypoxemia following acute pulmonary thromboembolism

John Y. C. Tsang,1 Wayne J. E. Lamm,3 Blazej Neradilek,4 Nayak L. Polissar,4 and Michael P. Hlastala2,3

1James Hogg iCAPTURE Research Laboratory, University of British Columbia, Vancouver, British Columbia, Canada; Departments of 2Physiology and Biophysics and 3Medicine, University of Washington, and 4The Mountain-Whisper-Light Statistical Consulting, Seattle, Washington

Submitted 12 September 2005 ; accepted in final form 10 October 2006

We studied the roles of endothelins in determining ventilation (VA) and perfusion (Q) mismatch in a porcine model of acute pulmonary thromboembolism (APTE), using a nonspecific endothelin antagonist, tezosentan. Nine anesthetized piglets (~23 kg) received autologous clots (~20 g) via a central venous catheter at time = 0 min. The distribution of VA and Q at five different time points (–30, –5, 30, 60, 120 min) was mapped by fluorescent microspheres of 10 different colors. Five piglets (group 1) received tezosentan (courtesy of Actelion) starting at time = 40 min for 2 h, and four piglets (group 2) received only saline and served as control. Our results showed that, in all of the animals at 30 min following APTE but before tezosentan, the mean VA/Q was increased, as was VA/Q heterogeneity (log SD VA/Q), which represented a widening of its main peak. Afterwards, tezosentan attenuated the pulmonary hypertension in group 1 but also produced moderate systemic hypotension. However, it did not improve arterial PO2 or VA/Q mismatch. We concluded that endothelin antagonism had minimal impact on gas exchange following APTE and confirmed our earlier observation that the main mechanism for hypoxemia in APTE was due to the mechanical redistribution of pulmonary regional blood flow away from the embolized vessels, resulting in the creation of many divergent low and high VA/Q regions.

cluster analysis; fluorescent microspheres; gas exchange; regional blood flow; regional ventilation



Address for reprint requests and other correspondence: J. Y. C. Tsang, James Hogg iCAPTURE Research Lab., St. Paul's Hospital, 1081 Burrard St., Vancouver, BC, Canada V6Z 1Y6 (e-mail: jtsang{at}interchange.ubc.ca)







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2007 by the American Physiological Society.