Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 101: 469-476, 2006. First published April 20, 2006; doi:10.1152/japplphysiol.00273.2006
8750-7587/06 $8.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow All Versions of this Article:
101/2/469    most recent
00273.2006v1
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kraman, S. S.
Right arrow Articles by Pasterkamp, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kraman, S. S.
Right arrow Articles by Pasterkamp, H.

Comparison of lung sound transducers using a bioacoustic transducer testing system

Steve S. Kraman,1 George R. Wodicka,2 Gary A. Pressler,2 and Hans Pasterkamp3

1Department of Internal Medicine, University of Kentucky, Lexington, Kentucky; 2Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana; and 3Department of Pediatrics and Child Health, University of Manitoba, Winnipeg, Manitoba, Canada

Submitted 2 March 2006 ; accepted in final form 10 April 2006

Sensors used for lung sound research are generally designed by the investigators or adapted from devices used in related fields. Their relative characteristics have never been defined. We employed an artificial chest wall with a viscoelastic surface and a white noise signal generator as a stable source of sound to compare the frequency response and pulse waveform reproduction of a selection of devices used for lung sound research. We used spectral estimation techniques to determine frequency response and cross-correlation of pulses to determine pulse shape fidelity. The sensors evaluated were the Siemens EMT 25 C accelerometer (Siemens); PPG 201 accelerometer (PPG); Sony ECM-T150 electret condenser microphone with air coupler (air coupler; with cylindrical air chambers of 5-, 10-, and 15-mm diameter and conical air chamber of 10-mm diameter); Littman classic stethoscope head (Littman) connected to an electret condenser microphone; and the Andries Tek (Andries) electronic stethoscope. We found that the size and shape of the air coupler chamber to have no important effect on the detected sound. The Siemens, air coupler, and Littman performed similarly with relatively flat frequency responses from 200 to 1,200 Hz. The PPG had the broadest frequency response, with useful sensitivity extending to 4,000 Hz. The Andries' frequency response was the poorest above 1,000 Hz. Accuracy in reproducing pulses roughly corresponded with the high-frequency sensitivity of the sensors. We conclude that there are important differences among commonly used lung sound sensors that have to be defined to allow the comparison of data from different laboratories.

respiratory sounds; respiratory acoustics; microphones; accelerometers



Address for reprint requests and other correspondence: S. S. Kraman, Univ. of Kentucky, Kentucky Clinic L-547, Lexington, KY 40536 (e-mail: sskram01{at}uky.edu)




This article has been cited by other articles:


Home page
Postgrad. Med. J.Home page
C. C Ceresa and I. D A Johnston
Auscultation in the diagnosis of respiratory disease in the 21st century
Postgrad. Med. J., August 1, 2008; 84(994): 393 - 394.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2006 by the American Physiological Society.