Journal of Applied Physiology AJP: Endocrinology and Metabolism
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 100: 1426-1427, 2006; doi:10.1152/japplphysiol.01207.2005
8750-7587/06 $8.00
This Article
Right arrow Full Text Free
Right arrow Full Text (PDF) Free
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ferrari, M.
Right arrow Articles by Crandall, C. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ferrari, M.
Right arrow Articles by Crandall, C. G.

LETTER TO THE EDITOR

Light source-detector spacing of near-infrared-based tissue oximeters and the influence of skin blood flow

ABSTRACT

Near-infrared (NIR) spectroscopy is a noninvasive optical technique that is increasingly used to assess muscle oxygenation during exercise with the assumption that the contribution of skin blood flow to the NIR signal is minor or nonexistent. We tested this assumption in humans by monitoring forearm tissue oxygenation during selective cutaneous vasodilation induced by locally applied heat (n = 6) or indirect whole body heating (i.e., heating subject but not area surrounding NIR probes; n = 8). Neither perturbation has been shown to cause a measurable change in muscle blood flow or metabolism. Local heating (~41°C) caused large increases in the NIR-derived tissue oxygenation signal [before heating = 0.82 ± 0.89 optical density (OD), after heating = 18.21 ± 2.44 OD; P < 0.001]. Similarly, whole body heating (increase internal temperature 0.9°C) also caused large increases in the tissue oxygenation signal (before heating = –0.31 ± 1.47 OD, after heating = 12.48 ± 1.82 OD; P < 0.001). These increases in the tissue oxygenation signal were closely correlated with increases in skin blood flow during both local heating (mean r = 0.95 ± 0.02) and whole body heating (mean r = 0.89 ± 0.04). These data suggest that the contribution of skin blood flow to NIR measurements of tissue oxygenation can be significant, potentially confounding interpretation of the NIR-derived signal during conditions where both skin and muscle blood flows are elevated concomitantly (e.g., high-intensity and/or prolonged exercise).


 

REPLY

Scott L. Davis,1,4 Paul J. Fadel,2 Jian Cui,3 Gail D. Thomas,4 and Craig G. Crandall1,4

1Institute for Exercise and Environmental Medicine
Presbyterian Hospital of Dallas
Dallas, Texas
e-mail: ScottDavis{at}texashealth.org 2Department of Medical Pharmacology and Physiology
University of Missouri
Columbia, Missouri 3Department of Cardiology
Penn State College of Medicine
Hershey, Pennsylvania 4Department of Internal Medicine
University of Texas Southwestern Medical Center
Dallas, Texas








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online
Copyright © 2006 by the American Physiological Society.